Quantification of N-acetylcysteine in pharmaceuticals using cobalt phthalocyanine modified graphite electrodes

被引:24
作者
da Silva, Iranaldo Santos [1 ,2 ]
Antao Araujo, Marcelo Fernando [3 ]
Ferreira, Henrique Augusto [3 ]
Gomes Varela, Jaldyr de Jesus, Jr. [4 ]
Carvalho Neiva Tanaka, Sonia Maria [3 ]
Tanaka, Auro Atsushi [3 ,5 ]
Angnes, Lucio [1 ]
机构
[1] Univ Sao Paulo, Inst Quim, BR-05508000 Sao Paulo, Brazil
[2] Companhia Aguas & Esgotos Maranhao, BR-65020906 Sao Luis, MA, Brazil
[3] Univ Fed Maranhao, Dept Quim, BR-65085580 Sao Luis, MA, Brazil
[4] Univ Fed Maranhao, Colegio Univ, BR-65085580 Sao Luis, MA, Brazil
[5] Inst Nacl Ciencia & Tecnol Bioanalt, BR-13083970 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
N-acetylcysteine; OPG-CoPc; Cobalt phthalocyanine; Voltammetry; Pharmaceuticals; ELECTROCATALYTIC ACTIVITY; STRIPPING VOLTAMMETRY; CARBON-PASTE; CYSTEINE; OXIDATION; CYSTINE; REDOX; METALLOPHTHALOCYANINES; FORMULATIONS; AMPEROMETRY;
D O I
10.1016/j.talanta.2010.11.070
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow injection analysis (FIA) with amperometric detection was employed for the quantification of N-acetylcysteine (NAC) in pharmaceutical formulations, utilizing an ordinary pyrolytic graphite (OPG) electrode modified with cobalt phthalocyanine (CoPc). Cyclic voltammetry was used in preliminary studies to establish the best conditions for NAC analysis. In FIA-amperometric experiments the OPG-CoPc electrode exhibited sharp and reproducible current peaks over a wide linear working range (5.0 x 10(-5)-1.0 x 10(-3) mol L-1) in 0.1 mol L-1 NaOH solution. High sensitivity (130 mA mol(-1) cm(2)) and a low detection limit (9.0 x 10(-7) mol L-1) were achieved using the sensor. The repeatability (R.S.D.%) for 13 successive flow injections of a solution containing 5.0 x 10(-4) mol L-1 NAC was 1.1%. The new procedure was applied in analyses of commercial pharmaceutical products and the results were in excellent agreement with those obtained using the official titrimetric method. The proposed amperometric method is highly suitable for quality control analyses of NAC in pharmaceuticals since it is rapid, precise and requires much less work than the recommended titrimetric method. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1701 / 1706
页数:6
相关论文
共 28 条
[1]  
Al-Ghannam SM, 2002, FARMACO, V57, P625
[2]   SPECTROPHOTOMETRIC DETERMINATION OF N-ACETYLCYSTEINE IN DRUG FORMULATIONS WITH O-PHTHALALDEHYDE AND ISOLEUCINE [J].
ALVAREZCOQUE, MCG ;
HERNANDEZ, MJM ;
CAMANAS, RMV ;
FERNANDEZ, CM .
ANALYST, 1989, 114 (08) :975-977
[3]  
[Anonymous], 1988, FARMACOPEIA BRASILEI
[4]   APPLICATION OF CATALYTIC STRIPPING VOLTAMMETRY FOR THE DETERMINATION OF ORGANIC SULFUR-COMPOUNDS AT A HANGING MERCURY DROP ELECTRODE - BEHAVIOR OF CYSTEINE, CYSTINE AND N-ACETYLCYSTEINE IN THE PRESENCE OF NICKEL ION [J].
BANICA, FG ;
MOREIRA, JC ;
FOGG, AG .
ANALYST, 1994, 119 (02) :309-318
[5]  
Bard A.J., 1980, LR Faulkner electrochemical methods. Fundamentais and Applications
[6]  
Carmo D.R., 2003, J BRAZIL CHEM SOC, V14, P616
[7]   Determination of N-acetylcysteine in human plasma by liquid chromatography coupled to tandem mass spectrometry [J].
Celma, C ;
Allué, JA ;
Pruñonosa, J ;
Peraire, C ;
Obach, R .
JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) :13-22
[8]   Investigation on the chemiluminescence reaction of luminol-H2O2-S2-/R-SH system [J].
Du, JX ;
Li, YH ;
Lu, JR .
ANALYTICA CHIMICA ACTA, 2001, 448 (1-2) :79-83
[9]   N-Acetylcysteine suppression of the proliferative index in the colon of patients with previous adenomatous colonic polyps [J].
Estensen, RD ;
Levy, M ;
Klopp, SJ ;
Galbraith, AR ;
Mandel, JS ;
Blomquist, JA ;
Wattenberg, LW .
CANCER LETTERS, 1999, 147 (1-2) :109-114
[10]   Fast and Accurate Analysis of Drugs Using Amperometry Associated With Flow Injection Analysis [J].
Felix, Fabiana S. ;
Angnes, Lucio .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2010, 99 (12) :4784-4804