Clinical, physiological, and radiological study of a new purpose-designed artificial bowel sphincter

被引:79
作者
Vaizey, CJ
Kamm, MA
Gold, DM
Bartram, CI
Halligan, S
Nicholls, RJ
机构
[1] St Marks Hosp, Dept Physiol, London EC1V 2PS, England
[2] St Marks Hosp, Dept Radiol, London EC1V 2PS, England
[3] St Marks Hosp, Dept Surg, London EC1V 2PS, England
关键词
D O I
10.1016/S0140-6736(97)11427-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Studies of the use of artificial urinary sphincters for faecal incontinence have led to refinement and adaptation of such sphincters to the anatomy of the anal region. We aimed to test this new device. Methods Six women, median age 53 (range 32-58) years, who were unsuitable for sphincter repair, had an artificial bowel sphincter implanted as a one-stage procedure without colostomy cover. Clinical assessment, physiological testing, and endosonography were done before and after the operation. Plain radiography, three-dimensional endosonography, and magnetic-resonance imaging were done after the operation, to define its anatomical location. Results Median follow-up was 10 (range 5-13) months and the device was functional in five patients. In one patient, the device was removed after ulceration through the skin, Of the patients with intact devices, Wexner incontinence scores improved from a median of 19 (18-20) of 20 before the operation, to 3 (0-6) of 20 after the operation, Median anal pressure at rest significantly increased from 60 (range 30-80) cm H2O to 110 (100-120) cm H2O, Functional anal-canal length varied after the operation from 3.3 cm to 3.8 cm. There was no significant change in the maximum tolerated volume of the rectum (140 [80-230] vs 100 [75-250] mt), or rectal compliance (2.9 [2.8-6.0] cm H2O/mL vs 3.5 [2.3-7.3] cm H2O/mL). All the imaging techniques accurately located the implant relative to the anal canal and pelvic floor in each patient. Interpretation The new artificial bowel sphincter provided a good functional result in five of the six patients, the surgical procedure was straightforward, and the maximum resting anal pressure rose without affecting rectal function. The ease of visualisation of such implants in situ should aid simple management of complications, should they arise.
引用
收藏
页码:105 / 109
页数:5
相关论文
共 13 条
[1]   ANAL DYNAMIC GRACILOPLASTY IN THE TREATMENT OF INTRACTABLE FECAL INCONTINENCE [J].
BAETEN, CGMI ;
GEERDES, BP ;
ADANG, EMM ;
HEINEMAN, E ;
KONSTEN, J ;
ENGEL, GL ;
KESTER, ADM ;
SPAANS, F ;
SOETERS, PB .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 332 (24) :1600-1605
[2]   IMPLANTATION OF ARTIFICIAL SPHINCTER FOR ANAL INCONTINENCE - REPORT OF 5 CASES [J].
CHRISTIANSEN, J ;
LORENTZEN, M .
DISEASES OF THE COLON & RECTUM, 1989, 32 (05) :432-436
[3]  
CHRISTIANSEN J, 1987, LANCET, V1, P244
[4]   Dynamic graciloplasty - Complications and management [J].
Geerdes, BP ;
Heineman, E ;
Soeters, PB ;
Baeten, CGMI .
DISEASES OF THE COLON & RECTUM, 1996, 39 (08) :912-917
[5]   ANORECTAL MANOMETRY - TECHNIQUES AND CLINICAL-APPLICATIONS [J].
JORGE, JMN ;
WEXNER, SD .
SOUTHERN MEDICAL JOURNAL, 1993, 86 (08) :924-931
[6]   RECTAL MUCOSAL ELECTROSENSORY TESTING - EVIDENCE FOR A RECTAL SENSORY NEUROPATHY IN IDIOPATHIC CONSTIPATION [J].
KAMM, MA ;
LENNARDJONES, JE .
DISEASES OF THE COLON & RECTUM, 1990, 33 (05) :419-423
[7]   SLOWED CONDUCTION IN THE PUDENDAL NERVES IN IDIOPATHIC (NEUROGENIC) FECAL INCONTINENCE [J].
KIFF, ES ;
SWASH, M .
BRITISH JOURNAL OF SURGERY, 1984, 71 (08) :614-616
[8]   Results of artificial sphincter in severe anal incontinence - Report of 14 consecutive implantations [J].
Lehur, PA ;
Michot, F ;
Denis, P ;
Grise, P ;
Leborgne, J ;
Teniere, P ;
Buzelin, JM .
DISEASES OF THE COLON & RECTUM, 1996, 39 (12) :1352-1355
[9]   SUCCESS OF THE NARROW-BACKED CUFF DESIGN OF THE AMS800 ARTIFICIAL URINARY SPHINCTER - ANALYSIS OF 144 PATIENTS [J].
LEO, ME ;
BARRETT, DM .
JOURNAL OF UROLOGY, 1993, 150 (05) :1412-1414
[10]  
MARCIO J, 1993, DIS COLON RECTUM, V36, P77