Reliability of the dye penetration studies

被引:106
作者
Camps, J
Pashley, D
机构
[1] Fac Odontol, Unite IMEB, F-13385 Marseille 5, France
[2] Med Coll Georgia, Sch Dent, Dept Oral & Maxillofacial Pathol, Augusta, GA 30912 USA
关键词
D O I
10.1097/00004770-200309000-00012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to compare the classical dye-penetration method to a dye-extraction method, with a fluid-filtration method as control. Forty teeth were prepared with a ProFile device and divided into four groups (n = 10 per group) according to the sealer used for the lateral condensation: Pulp Canal Sealer, Sealapex, AH Plus, and Ketac-Endo. The apical seal was evaluated on the same teeth with all three methods, successively: a fluid-filtration method, a dye-penetration method with 2% methylene blue, and a new method where the roots were dissolved in 65% nitric acid to extract the methylene blue before reading the absorbance of the solution. The classical dye penetration did not show any difference among the sealers and showed no correlation with the two other techniques. The fluid filtration (p < 0.01) and the dye extraction (p < 0.01) showed that Sealapex displayed the highest apical leakage. The correlation between the results obtained with these two methods was significant (p = 0.001 and r = 0.7). This study showed the limitation of the classical dye-penetration studies and that the dye-extraction, i.e. dissolution, method gave the same results as fluid filtration but saved much laboratory time.
引用
收藏
页码:592 / 594
页数:3
相关论文
共 16 条
[1]   MICROLEAKAGE OF 3 TEMPORARY ENDODONTIC RESTORATIONS [J].
ANDERSON, RW ;
POWELL, BJ ;
PASHLEY, DH .
JOURNAL OF ENDODONTICS, 1988, 14 (10) :497-501
[2]   Bacterial leakage versus dye leakage in obturated root canals [J].
Barthel, CR ;
Moshonov, J ;
Shuping, G ;
Orstavik, D .
INTERNATIONAL ENDODONTIC JOURNAL, 1999, 32 (05) :370-375
[3]  
DEGEE AJ, 1994, INT ENDOD J, V27, P239
[4]   Influence of criteria on the results of in vitro evaluation of microleakage [J].
Dejou, J ;
Sindres, V ;
Camps, J .
DENTAL MATERIALS, 1996, 12 (5-6) :342-349
[5]   COMPARISON AND RELIABILITY OF TECHNIQUES FOR MEASURING LEAKAGE AND MARGINAL PENETRATION [J].
DELIVANIS, PD ;
CHAPMAN, KA .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1982, 53 (04) :410-416
[6]  
Gale M, 1998, P ACAD DENT MAT, V11, P118
[7]   QUANTITATIVE MICROLEAKAGE OF SOME DENTINAL BONDING RESTORATIVE SYSTEMS [J].
HASEGAWA, T ;
RETIEF, DH .
DENTAL MATERIALS, 1993, 9 (02) :114-117
[8]   EFFECTS OF VACUUMING ON DYE PENETRATION PATTERNS IN ROOT CANALS AND GLASS TUBES [J].
MASTERS, J ;
HIGA, R ;
TORABINEJAD, M .
JOURNAL OF ENDODONTICS, 1995, 21 (06) :332-334
[9]  
MATLOFF IR, 1982, ORAL SURG ORAL PATHO, P203
[10]   The sealing ability of Thermafil obturators assessed by four different microleakage techniques [J].
Pathomvanich, S ;
Edmunds, DH .
INTERNATIONAL ENDODONTIC JOURNAL, 1996, 29 (05) :327-334