Evaluation of a flow injection system combined with an inductively coupled plasma mass spectrometer with thermospray nebulization for the determination of trace levels of platinum

被引:28
作者
Parent, M [1 ]
Vanhoe, H [1 ]
Moens, L [1 ]
Dams, R [1 ]
机构
[1] STATE UNIV GHENT,INST NUCL SCI,ANALYT CHEM LAB,B-9000 GHENT,BELGIUM
关键词
flow injection; thermospray nebulization; inductively coupled plasma-mass spectrometry; platinum; calibration;
D O I
10.1016/0003-2670(95)00525-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper the coupling of a flow injection system to an inductively coupled plasma mass spectrometer using thermospray nebulization for the determination of platinum is evaluated. The results are compared with pneumatic nebulization. The flow injection system provides the possibility of on-line sample dilution and on-line standardization. A comparative study was made between on-line isotope dilution, on-line standard additions and external calibration emphasizing accuracy, precision and flexibility of the method. Several parameters of thermospray and flow injection were evaluated. Sensitivity, background and detection limits were studied as well as the peak integration method to be used with the now injection system. The detection limits, using flow injection (200 mu l loop) and partial integration of the peak, were in the range of 25 ng/l (5 pg absolute) and 8 ng/l (2 pg absolute) for pneumatic and thermospray nebulization, respectively. The optimized procedure was used for the analysis of Pt in corn leaves, mouse liver and a Ca-3(PO4)(2) matrix.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 27 条
[1]  
ALT F, 1988, MIKROCHIM ACTA, V3, P299
[2]  
ALT F, 1990, SCHLUSSBERICHT FORSC
[4]   THERMOSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BLAKLEY, CR ;
VESTAL, ML .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :750-754
[5]   CHARACTERISTICS OF FLOW-INJECTION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY FOR TRACE-METAL ANALYSIS [J].
DEAN, JR ;
EBDON, L ;
CREWS, HM ;
MASSEY, RC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (02) :349-354
[6]  
DENOYER ER, 1993, ATOM SPECTROSC, V14, P162
[7]   DETERMINATION OF LEAD BY FLOW-INJECTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY COMPARING SEVERAL CALIBRATION TECHNIQUES [J].
GOOSSENS, J ;
MOENS, L ;
DAMS, R .
ANALYTICA CHIMICA ACTA, 1994, 293 (1-2) :171-181
[9]   HYDRAULIC HIGH-PRESSURE NEBULIZATION - APPLICATION OF A NEW NEBULIZATION SYSTEM FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
JAKUBOWSKI, N ;
FELDMANN, I ;
STUEWER, D ;
BERNDT, H .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (01) :119-129
[10]   FUNDAMENTAL CHARACTERISTICS OF THERMOSPRAY AEROSOLS AND SAMPLE INTRODUCTION FOR ATOMIC SPECTROMETRY [J].
KOROPCHAK, JA ;
WINN, DH .
APPLIED SPECTROSCOPY, 1987, 41 (08) :1311-1318