Integrated FIA for the determination of ascorbic acid and dehydroascorbic acid in a microfabricated glass-channel by thermal-lens microscopy

被引:50
作者
Sorouraddin, HM
Hibara, A
Proskurnin, MA
Kitamori, T [1 ]
机构
[1] Univ Tokyo, Sch Engn, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
[2] Kanagawa Acad Sci & Technol, Integrated Chem Project, Takatsu Ku, Kawasaki, Kanagawa 2130012, Japan
[3] Tabriz Univ, Fac Chem, Tabriz, Iran
[4] Moscow State Univ, Anal Chem Div, Moscow, Russia
关键词
D O I
10.2116/analsci.16.1033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-chip chemical micro-determination device, integrating the FIA system, was applied to L-ascorbic acid (AA) and dehydroascorbic acid (DHAA) determination. Microchannels having a 250x100 mum cross-section were fabricated in a quarts glass chip as a component in an integrated FIA system. They were put to use for flow, mixing, reaction, and detection. The reaction system was a coupled redox-complexation reaction between AA and a 1,10-phenantroline-Fe(III) mixture. Sample solutions were introduced into micro-channels by micro-syringes, the flow rate was controlled by a micro-syringe pump, and the reagents, were mixed by molecular diffusion. A photothermal microscope was used for the ultra-sensitive detection of the non-fluorescent reaction product (ferroin). For DHAA determination, dithiothreithol was used as a reducing agent and the total AA was determined. The DHAA quantity was calculated by subtraction. This method allows for the determination of AA with a linear range of up to 40 muM. The RSD for 25 muM AA (n=5) is 1%, and the limit of detection (LOD) is 0.1 muM. The procedure was successfully applied to determining the AA and DHAA content of urine and AA in vitamin C tablets. The results agree well with those obtained by reference methods.
引用
收藏
页码:1033 / 1037
页数:5
相关论文
共 32 条
[1]   A FACILE AND SENSITIVE SPECTROPHOTOMETRIC DETERMINATION OF ASCORBIC-ACID [J].
BESADA, A .
TALANTA, 1987, 34 (08) :731-732
[2]  
BISHOP E, 1972, INDICATORS, P543
[3]  
BODE AM, 1990, CLIN CHEM, V36, P1807
[4]  
BURITS CA, 1994, CLIN CHEM, P1311
[5]  
Carr AC, 1999, AM J CLIN NUTR, V69, P1086
[6]   Flow injection determination of L-ascorbic acid in natural juice with biamperometric detection [J].
Cheregi, M ;
Danet, AF .
ANALYTICAL LETTERS, 1997, 30 (14) :2625-2640
[7]   Use of column with modified silica for interfering retention in a FIA spectrophotometric method for direct determination of vitamin C in medicine [J].
Fernandes, JCB ;
Neto, GD ;
Kubota, LT .
ANALYTICA CHIMICA ACTA, 1998, 366 (1-3) :11-22
[8]   APPLICATION OF SQUARE-WAVE VOLTAMMETRY FOR THE DETERMINATION OF ASCORBIC-ACID IN SOFT DRINKS AND FRUIT JUICES USING A FLOW-INJECTION SYSTEM [J].
FUNG, YS ;
MO, SY .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :375-380
[9]   Sub-attomole molecule detection in a single biological cell in-vitro by thermal lens microscopy [J].
Harada, M ;
Shibata, M ;
Kitamori, T ;
Sawada, T .
ANALYTICAL SCIENCES, 1999, 15 (07) :647-650
[10]   APPLICATION OF COAXIAL BEAM PHOTOTHERMAL MICROSCOPY TO THE ANALYSIS OF A SINGLE BIOLOGICAL CELL IN WATER [J].
HARADA, M ;
SHIBATA, M ;
KITAMORI, T ;
SAWADA, T .
ANALYTICA CHIMICA ACTA, 1995, 299 (03) :343-347