Coherent use of opposing lenses for axial resolution increase in fluorescence microscopy. I. Comparative study of concepts

被引:61
作者
Nagorni, M [1 ]
Hell, SW [1 ]
机构
[1] Max Planck Inst Biophys Chem, High Resolut Opt Microscopy Grp, D-37070 Gottingen, Germany
关键词
D O I
10.1364/JOSAA.18.000036
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We study the use of coherent counterpropagating interfering waves to increase threefold to sevenfold the optical bandwidth and the resolution of fluorescence microscopy along the optic axis. Systematic comparison of the point-spread function and the optical transfer function (OTF) for the standing-wave microscope (SWM), the incoherent illumination interference image interference microscope ((IM)-M-5), and the 4Pi confocal microscope reveals essential differences among their resolution capabilities. It is shown that the OTF's of these microscopes differ strongly in contiguity and amplitude within the enlarged range of transferred frequencies, and therefore they also differ in their ability to provide data from which interference artifacts can be removed. We demonstrate that for practical aperture angles the production of an interference pattern is insufficient for improving the axial resolution by the expected factor of 3-7. Conditions of the OTF for unambiguous improvement of axial resolution of arbitrary objects are fulfilled not at all in the SWM, partially in the I5M, and fully in the two-photon 4Pi confocal microscope. (C) 2001 Optical Society of America.
引用
收藏
页码:36 / 48
页数:13
相关论文
共 32 条
[1]   Polarization effects in 4Pi confocal microscopy studied with water-immersion lenses [J].
Bahlmann, K ;
Hell, SW .
APPLIED OPTICS, 2000, 39 (10) :1652-1658
[2]  
BAHLMANN K, IN PRESS ULTRAMICROS
[3]   ENHANCEMENT OF AXIAL RESOLUTION IN FLUORESCENCE MICROSCOPY BY STANDING-WAVE EXCITATION [J].
BAILEY, B ;
FARKAS, DL ;
TAYLOR, DL ;
LANNI, F .
NATURE, 1993, 366 (6450) :44-48
[4]   3-DIMENSIONAL IMAGE-RESTORATION AND SUPERRESOLUTION IN FLUORESCENCE CONFOCAL MICROSCOPY [J].
BERTERO, M ;
BOCCACCI, P ;
BRAKENHOFF, GJ ;
MALFANTI, F ;
VANDERVOORT, HTM .
JOURNAL OF MICROSCOPY, 1990, 157 :3-20
[5]  
Born M., 1993, PRINCIPLES OPTICS
[6]   2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY [J].
DENK, W ;
STRICKLER, JH ;
WEBB, WW .
SCIENCE, 1990, 248 (4951) :73-76
[7]   Development of a standing-wave fluorescence microscope with high nodal plane flatness [J].
Freimann, R ;
Pentz, S ;
Horler, H .
JOURNAL OF MICROSCOPY-OXFORD, 1997, 187 :193-200
[8]   3-DIMENSIONAL TRANSFER-FUNCTIONS IN 4PI CONFOCAL MICROSCOPES [J].
GU, M ;
SHEPPARD, CJR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (05) :1619-1627
[9]  
GU M, 1996, PRINCIPLES 3 DIMENSI, P142
[10]  
Gustafsson MGL, 1999, J MICROSC-OXFORD, V195, P10, DOI 10.1046/j.1365-2818.1999.00576.x