Electrochemical methods for simultaneous determination of dopamine and ascorbic acid using cetylpyridine bromide/chitosan composite film-modified glassy carbon electrode

被引:105
作者
Cao, Xiaomei [1 ]
Luo, Liqiang [1 ]
Ding, Yaping [1 ]
Zou, Xuelian [1 ]
Bian, Ruixiang [1 ]
机构
[1] Shanghai Univ, Dept Chem, Shanghai 200444, Peoples R China
基金
中国国家自然科学基金;
关键词
cetylpyridine bromide; chitosan; simultaneous determination; dopamine; ascorbic acid; SIMULTANEOUS VOLTAMMETRIC DETECTION; URIC-ACID; SELECTIVE DETERMINATION; GOLD ELECTRODE; PASTE ELECTRODE; SURFACTANT; MONOLAYERS; SEROTONIN;
D O I
10.1016/j.snb.2007.10.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, cetylpyridine bromide (CPB)/chitosan composite film-modified glassy carbon electrode (GCE) is developed for simultaneous determination of dopamine (DA) and ascorbic acid (AA) by differential pulse voltammetry (DPV). At CPB/chitosan composite film-modified GCE, the oxidation peak potential of AA shifts toward less positive potential and the peak current of AA increases greatly, while the oxidation peak potential of DA shifts toward more positive potential and peak current decreases greatly in comparison with that on bare electrode. Therefore, the common overlapped oxidation peaks of AA and DA can be separated completely by using CPB/chitosan composite film-modified electrode. For AA and DA in mixture, one can well separates from the other with potential difference of about 0.3 V, which is large enough to allow determination of one in the presence of the other. Under the optimum conditions, the anodic peak currents (I-pa) of DPV are proportional to the concentration of AA in the range of 1.0 x 10(-5) to 2.0 x 10(-3)M, and to that of DA in the range of 4.0 x 10(-5) to 5.0 x 10(-3) M. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:941 / 946
页数:6
相关论文
共 30 条
[1]   Simultaneous voltammetric detection of dopamine and ascorbic acid using didodecyldimethylammonium bromide (DDAB) film-modified electrodes [J].
Chen, SM ;
Chzo, WY .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 587 (02) :226-234
[2]   Exploiting micellar environment for simultaneous electrochemical determination of ascorbic acid and dopamine [J].
dos Reis, AP ;
Tarley, CRT ;
Maniasso, N ;
Kubota, LT .
TALANTA, 2005, 67 (04) :829-835
[3]   Dopamine voltammetry at overoxidised polyindole electrodes [J].
Ghita, M ;
Arrigan, DWM .
ELECTROCHIMICA ACTA, 2004, 49 (26) :4743-4751
[4]   Selective response of dopamine in the presence of ascorbic acid on L-cysteine self-assembled gold electrode [J].
Hu, Guangzhi ;
Liu, Yunchun ;
Zhao, Jun ;
Cui, Shiqiang ;
Yang, Zhousheng ;
Zhang, Yuzhong .
BIOELECTROCHEMISTRY, 2006, 69 (02) :254-257
[5]   Electrochemical properties of ordered mesoporous carbon and its electroanalytical application for selective determination of dopamine [J].
Jia, Nengqin ;
Wang, Zhiyong ;
Yang, Guofeng ;
Shen, Hebai ;
Zhu, Longzhang .
ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (02) :233-238
[6]   Novel choline and acetylcholine modified glassy carbon electrodes for simultaneous determination of dopamine, serotonin and ascorbic acid [J].
Jin, GP ;
Lin, XQ ;
Gong, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 569 (01) :135-142
[7]   Poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode for simultaneous detection of dopamine and ascorbic acid [J].
Jin, GY ;
Zhang, YH ;
Cheng, WX .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 107 (02) :528-534
[8]   Simultaneous electroanalysis of dopamine, ascorbic acid and uric acid by poly (vinyl alcohol) covalently modified glassy carbon electrode [J].
Li, YX ;
Lin, XQ .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 115 (01) :134-139
[9]   Biosensing properties of titanate-nanotube films: Selective detection of dopamine in the presence of ascorbate and uric acid [J].
Liu, AH ;
Wei, MD ;
Honma, I ;
Zhou, HS .
ADVANCED FUNCTIONAL MATERIALS, 2006, 16 (03) :371-376
[10]   Simultaneous voltammetric detection of dopamine and uric acid at their physiological level in the presence of ascorbic acid using poly(acrylic acid)-multiwalled carbon-nanotube composite-covered glassy-carbon electrode [J].
Liu, Aihua ;
Honma, Itaru ;
Zhou, Haoshen .
BIOSENSORS & BIOELECTRONICS, 2007, 23 (01) :74-80