Reproducibility of electromyographic recordings of submaximal concentric and eccentric muscle contractions in humans

被引:27
作者
Finucane, SDG [1 ]
Rafeei, T [1 ]
Kues, J [1 ]
Lamb, RL [1 ]
Mayhew, TP [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Phys Therapy, Richmond, VA 23298 USA
来源
ELECTROMYOGRAPHY AND MOTOR CONTROL-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY | 1998年 / 109卷 / 04期
关键词
surface electromyography; reliability; concentric contraction; eccentric contraction; normalization; measurement;
D O I
10.1016/S0924-980X(98)00020-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives: to determine the intratester and intertester reliability of measures of electromyographic activity (EMG) of submaximal concentric and eccentric contractions and to compare the reliability of normalized and non-normalized measures of EMG. There were 10 subjects, of 22-33 years old. Methods: Subjects performed submaximal concentric and eccentric contractions at 60 degrees/s, and maximal isometric contractions (MIC) of their knee extensors. The target power of the submaximal contractions was 90% +/- 10% of the subject's maximal concentric power. EMG was recorded via bipolar surface electrodes from 3 of the quadriceps femoris muscles. The rmsEMG for submaximal contractions that were within the target power range were determined. The rmsEMG for the submaximal contractions were normalized to the rmsEMG of the maximal isometric contractions. Intraclass correlation coefficients (ICC version 1.1) were calculated to determine intratester and intertester reliability. Results: For non-normalized rmsEMG, ICC values for intratester reliability ranged from 0.62 to 0.91 for concentric and from 0.84 to 0.97 for eccentric contractions. ICC values for intertester reliability ranged from 0.66 to 0.96 for concentric and 0.78 to 0.90 for eccentric contractions. Conclusions: Non-normalized rmsEMG of submaximal concentric and eccentric isokinetic contractions were found to be reliable. Normalization did not lead to consistently improved reliability. (C) 1998 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:290 / 296
页数:7
相关论文
共 22 条
[1]   Normalizing upper trapezius EMG amplitude: Comparison of different procedures [J].
Bao, SH ;
Mathiassen, SE ;
Winkel, J .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1995, 5 (04) :251-257
[2]  
Basmajian J.V., 1985, Muscles Alive: Their Functions Revealed by Electromyography
[3]  
DELITTO A, 1991, AM PHYS THER ASS RES, V24, P2
[4]   EVALUATION OF THE GRAVITY-CORRECTION FEATURE OF A KIN-COM(R) ISOKINETIC DYNAMOMETER [J].
FINUCANE, SDG ;
MAYHEW, TP ;
ROTHSTEIN, JM .
PHYSICAL THERAPY, 1994, 74 (12) :1125-1133
[5]  
Fleiss J. L., 1999, The Design and Analysis of Clinical Experiments, DOI [DOI 10.1002/9781118032923, 10.1002/9781118032923]
[6]  
GERLEMAN DG, 1992, DHHS NIOSH PUBLICATI, P44
[7]   REPRODUCIBILITY OF ELECTROMYOGRAPHIC PATTERNS IN STRETCH-SHORTENING TYPE CONTRACTIONS [J].
GOLLHOFER, A ;
HORSTMANN, GA ;
SCHMIDTBLEICHER, D ;
SCHONTHAL, D .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1990, 60 (01) :7-14
[8]   Assessment of jet pilots' upper trapezius load calibrated to maximal voluntary contraction and a standardized load [J].
HarmsRingdahl, K ;
Ekholm, J ;
Schuldt, K ;
Linder, J ;
Ericson, MO .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1996, 6 (01) :67-72
[9]   The effects of normalization method on antagonistic activity patterns during eccentric and concentric isokinetic knee extension and flexion [J].
Kellis, E ;
Baltzopoulos, V .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1996, 6 (04) :235-245
[10]  
KOMI RV, 1970, ELECTROMYOGR CLIN NE, V4, P357