Development of an electrothermal vaporization ICP-MS method and assessment of its applicability to studies of the homogeneity of reference materials

被引:18
作者
Friese, KC
Grobecker, KH
Wätjen, U
机构
[1] Analyt Jena AG, D-07745 Jena, Germany
[2] Inst Reference Mat & Measurements, Geel, Belgium
关键词
D O I
10.1007/s002160100868
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method has been developed for measurement of the homogeneity of analyte distribution in powdered materials by use of electrothermal vaporization with inductively coupled plasma mass spectrometric (ETV-ICP-MS) detection. The method enabled the simultaneous determination of As, Cd, Cu, Fe, Mn, Pb, and Zn in milligram amounts of samples of biological origin. The optimized conditions comprised a high plasma power of 1500 W, reduced aerosol transport flow, and heating ramps below 300 degreesC s(-1). A temperature ramp to 550 degreesC ensured effective pyrolysis of approximately 70% of the organic compounds without losses of analyte. An additional hold stage at 700 degreesC led to separation of most of the analyte signals from the evaporation of carbonaceous matrix compounds. The effect of time resolution of signal acquisition on the precision of the ETV measurements was investigated. An increase in the number of masses monitored up to 20 is possible with not more than 1 % additional relative standard deviation of results caused by limited temporal resolution of the transient signals. Recording of signals from the nebulization of aqueous standards in each sample run enabled correction for drift of the sensitivity of the ETV-ICP-MS instrument. The applicability of the developed method to homogeneity studies was assessed by use of four certified reference materials. According to the best repeatability observed in these sample runs, the maximum contribution of the method to the standard deviation is approximately 5% to 6% for all the elements investigated.
引用
收藏
页码:499 / 507
页数:9
相关论文
共 13 条
[1]  
*CRC, 1981, CRC HDB CHEM PHYS, pB85
[2]  
FRIESE KC, 2001, IN PRESS FRESENIUS J
[3]  
HASSLER J, 1998, P 14 SEM AT SPECTR H, P128
[4]   SEAWATER AS A MULTICOMPONENT PHYSICAL CARRIER FOR ETV-ICP-MS [J].
HUGHES, DM ;
CHAKRABARTI, CL ;
GOLTZ, DM ;
GREGOIRE, DC ;
STURGEON, RE ;
BYRNE, JP .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (4-7) :425-440
[5]   INTERPRETING SOME ANALYTICAL CHARACTERISTICS OF THERMAL DISPERSION METHODS USED FOR SAMPLE INTRODUCTION IN ATOMIC SPECTROMETRY [J].
KANTOR, T .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (9-11) :1299-1320
[6]   MICROHETEROGENEITY OF TRACE-ELEMENTS IN REFERENCE MATERIALS - DETERMINATION AND STATISTICAL EVALUATION [J].
KURFURST, U ;
PAUWELS, J ;
GROBECKER, KH ;
STOEPPLER, M ;
MUNTAU, H .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (2-4) :112-120
[7]   HOMOGENEITY DETERMINATION OF CD IN PLASTIC CRMS USING SOLID SAMPLING ATOMIC-ABSORPTION SPECTROMETRY [J].
PAUWELS, J ;
HOFMANN, C ;
GROBECKER, KH .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (07) :475-477
[8]   DETERMINATION OF THE MINIMUM SAMPLE MASS OF A SOLID CRM TO BE USED IN CHEMICAL-ANALYSIS [J].
PAUWELS, J ;
VANDECASTEELE, C .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (2-4) :121-123
[9]  
PERLZ P, 2000, Patent No. 19837831
[10]   Simultaneous determination of Co, Mn, P and Ti in PET samples by solid sampling electrothermal vaporization ICP-MS [J].
Resano, M ;
Verstraete, M ;
Vanhaecke, F ;
Moens, L ;
van Alphen, A ;
Denoyer, ER .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (04) :389-395