A method has been developed to monitor the interaction between a lipopolysaccharide (LPS) and LPS-binding peptides using a piezoelectric quartz crystal (PQC). Different pH conditions were evaluated to coat LPS onto AT-cut crystals that had been sputtered with gold and carboxylated with a 4,4-dithiodi(n-butyric acid). The optimal pH for LPS coating onto the crystal was 4-5. Synthetic peptides that represent different regions of human bactericidal/permeability-increasing protein, BPI (BPI 85-99, BPI 90-101, BPI 157-167) and polymyxin B (PmB) as well as negative control peptide (HBsAg 139-147) were utilized to compare their binding ability to this LPS-coated PQC sensor. The results showed that PmB gave the greatest decrease to the resonant frequency indicating greatest binding ability. BPI 85-99, considered the main part of the LPS binding domain of BPI, was the next greatest, while BPI 157-167 and HBsAg 139-147 showed little response. In addition, BPI 90-101 and PmB-mimicking peptide showed intermediate LPS-binding ability, which was less than that of BPI 85-99, but was higher than that of BPI 157-167. These results suggest the PQC biosensor is potentially useful for the detection and comparison of the LPS-binding ability of different peptides by using an LPS-coated piezoelectric crystal.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 16 条
[1]  
GRAY PW, 1989, J BIOL CHEM, V264, P9505
[2]   A NOVEL IMMUNOSENSOR FOR HERPES VIRUSES [J].
KONIG, B ;
GRATZEL, M .
ANALYTICAL CHEMISTRY, 1994, 66 (03) :341-344
[3]  
LITTLE RG, 1994, J BIOL CHEM, V269, P1865
[4]  
MARRA MN, 1992, J IMMUNOL, V148, P532
[5]  
MICHAEL P, 1992, ENZYME MICROBIOL TEC, V14, P230
[6]   THE QUARTZ-CRYSTAL MICROBALANCE AS BIOSENSOR - A STATUS-REPORT ON ITS FUTURE [J].
MINUNNI, M ;
MASCINI, M ;
GUILBAULT, GG ;
HOCK, B .
ANALYTICAL LETTERS, 1995, 28 (05) :749-764
[7]  
MORRISON DC, 1978, AM J PATHOL, V93, P526
[8]   PIEZOELECTRIC CRYSTAL BIOSENSOR MODIFIED WITH PROTEIN-A FOR DETERMINATION OF IMMUNOGLOBULINS [J].
MURAMATSU, H ;
DICKS, JM ;
TAMIYA, E ;
KARUBE, I .
ANALYTICAL CHEMISTRY, 1987, 59 (23) :2760-2763
[9]   FUNDAMENTAL-STUDIES OF THE CHEMISORPTION OF ORGANOSULFUR COMPOUNDS ON AU(111) - IMPLICATIONS FOR MOLECULAR SELF-ASSEMBLY ON GOLD SURFACES [J].
NUZZO, RG ;
ZEGARSKI, BR ;
DUBOIS, LH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1987, 109 (03) :733-740
[10]  
RAETZ CRH, 1990, ANNU REV BIOCHEM, V59, P129, DOI 10.1146/annurev.bi.59.070190.001021