Effects of storage and type of blood collection tubes on hepatitis C virus level in whole blood samples

被引:20
作者
Kessler, HH
Stelzl, E
Raggam, RB
Haas, J
Kirchmeir, F
Hegenbarth, K
Daghofer, E
Santner, BI
Marth, E
Stauber, RE
机构
[1] Karl Franzens Univ Graz, Inst Hyg, Mol Diagnost Lab, A-8010 Graz, Austria
[2] Karl Franzens Univ Graz, Dept Obstet & Gynecol, Biometry Unit, A-8036 Graz, Austria
[3] Karl Franzens Univ Graz, Dept Internal Med, Div Gastroenterol & Hepatol, A-8036 Graz, Austria
[4] Greiner Bio One GMBH, A-4550 Kremsmunster, Austria
关键词
D O I
10.1128/JCM.39.5.1788-1790.2001
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
In this study, we compared serum hepatitis C virus (HCV) RNA concentrations,vith HCV RNA concentrations in whole blood collection tubes, including two different types of EDTA tubes and nucleic acid stabilization tubes (NASTs), We also investigated the impact of a processing delay on HCV RNA concentration in these tubes. In NASTs, the mean HCV RNA concentration was comparable to the mean serum HCV RNA concentration at "date zero." In EDTA tubes, mean baseline HCV RNA concentrations were higher, Storage at room temperature up to 96 h did not result in a decline of HCV RNA concentration in any of the whole blood collection tubes. In NASTs, HCV RNA concentrations remained stable during the whole study period, whereas a significant increase of HCV RNA was observed in both types of EDTA tubes at 96 h compared to date zero. We concluded that HCV RNA remains stable in NASTs at room temperature for at least 96 h, allowing greater flexibility in sample collection and transport.
引用
收藏
页码:1788 / 1790
页数:3
相关论文
共 23 条
[1]   Performance of an automated system for quantification of hepatitis C virus RNA [J].
Afonso, AMR ;
Didier, J ;
Plouvier, E ;
Falissard, B ;
Ferey, MP ;
Bogard, M ;
Dussaix, E .
JOURNAL OF VIROLOGICAL METHODS, 2000, 86 (01) :55-60
[2]   A ROLE FOR HEPATITIS-C VIRUS-INFECTION IN TYPE-II CRYOGLOBULINEMIA [J].
AGNELLO, V ;
CHUNG, RT ;
KAPLAN, LM .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 327 (21) :1490-1495
[3]   Multicenter evaluation of the COBAS AMPLICOR HCV assay, an integrated PCR system for rapid detection of hepatitis C virus RNA in the diagnostic laboratory [J].
Albadalejo, J ;
Alonso, R ;
Antinozzi, R ;
Bogard, M ;
Bourgault, AM ;
Colucci, G ;
Fenner, T ;
Petersen, H ;
Sala, E ;
Vincelette, J ;
Young, C .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (04) :862-865
[4]   HEPATITIS-C VIRUS IS DETECTED IN A MONOCYTE MACROPHAGE SUBPOPULATION OF PERIPHERAL-BLOOD MONONUCLEAR-CELLS OF INFECTED PATIENTS [J].
BOUFFARD, P ;
HAYASHI, PH ;
ACEVEDO, R ;
LEVY, N ;
ZELDIS, JB .
JOURNAL OF INFECTIOUS DISEASES, 1992, 166 (06) :1276-1280
[5]   HEPATITIS-C VIRUS - THE MAJOR CAUSATIVE AGENT OF VIRAL NON-A, NON-B HEPATITIS [J].
CHOO, QL ;
WEINER, AJ ;
OVERBY, LR ;
KUO, G ;
HOUGHTON, M ;
BRADLEY, DW .
BRITISH MEDICAL BULLETIN, 1990, 46 (02) :423-441
[6]  
COLOMBO M, 1989, LANCET, V2, P1006
[7]   STORAGE-CONDITIONS OF BLOOD-SAMPLES AND PRIMER SELECTION AFFECT THE YIELD OF CDNA POLYMERASE CHAIN-REACTION PRODUCTS OF HEPATITIS-C VIRUS [J].
CUYPERS, HTM ;
BRESTERS, D ;
WINKEL, IN ;
REESINK, HW ;
WEINER, AJ ;
HOUGHTON, M ;
VANDERPOEL, CL ;
LESLIE, PN .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (12) :3220-3224
[8]   Stability of hepatitis C virus RNA during specimen handling and storage prior to NASBA amplification [J].
Damen, M ;
Sillekens, P ;
Sjerps, M ;
Melsert, R ;
Frantzen, I ;
Reesink, HW ;
Lelie, PN ;
Cuypers, HTM .
JOURNAL OF VIROLOGICAL METHODS, 1998, 72 (02) :175-184
[9]  
DANA F, 1994, POSTGRAD MED, V95, P125
[10]  
DOCKTER J, 1998, TRANSFUSION S, V38, pS246