Does Platelet-Rich Plasma Accelerate Recovery After Rotator Cuff Repair? A Prospective Cohort Study

被引:152
作者
Jo, Chris Hyunchul [1 ]
Kim, Ji Eun [1 ]
Yoon, Kang Sup [1 ]
Lee, Ji Ho [1 ]
Kang, Seung Baik [1 ]
Lee, Jae Hyup [1 ]
Han, Hyuk Soo [1 ]
Rhee, Seung Hwan [1 ]
Shin, Sue [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Orthoped Surg, SMG SNU Boramae Med Ctr, Seoul 156707, South Korea
关键词
platelet-rich plasma; rotator cuff tear; rotator cuff repair; growth factors; tendon healing; GROWTH-FACTORS; PATIENT SATISFACTION; TENDON; BONE; LIGAMENT; GEL; SUPRASPINATUS; AUGMENTATION; EXPRESSION; INTEGRITY;
D O I
10.1177/0363546511413454
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: Platelet-rich plasma (PRP) has been recently used to enhance and accelerate the healing of musculoskeletal injuries and diseases, but evidence is still lacking, especially on its effects after rotator cuff repair. Hypothesis: Platelet-rich plasma accelerates recovery after arthroscopic rotator cuff repair in pain relief, functional outcome, overall satisfaction, and enhanced structural integrity of repaired tendon. Study Design: Cohort study; Level of evidence, 2. Methods: Forty-two patients with full-thickness rotator cuff tears were included. Patients were informed about the use of PRP before surgery and decided themselves whether to have PRP placed at the time of surgery. Nineteen patients underwent arthroscopic rotator cuff repair with PRP and 23 without. Platelet-rich plasma was prepared via plateletpheresis and applied in the form of a gel threaded to a suture and placed at the interface between tendon and bone. Outcomes were assessed preoperatively and at 3, 6, 12, and finally at a minimum of 16 months after surgery (at an average of 19.7 +/- 1.9 months) with respect to pain, range of motion, strength, and overall satisfaction, and with respect to functional scores as determined using the following scoring systems: the American Shoulder and Elbow Surgeon (ASES) system, the Constant system, the University of California at Los Angeles (UCLA) system, the Disabilities of the Arm, Shoulder and Hand (DASH) system, the Simple Shoulder Test (SST) system, and the Shoulder Pain and Disability Index (SPADI) system. At a minimum of 9 months after surgery, repaired tendon structural integrities were assessed by magnetic resonance imaging. Results: Platelet-rich plasma gel application to arthroscopic rotator cuff repairs did not accelerate recovery with respect to pain, range of motion, strength, functional scores, or overall satisfaction as compared with conventional repair at any time point. Whereas magnetic resonance imaging demonstrated a retear rate of 26.7% in the PRP group and 41.2% in the conventional group, there was no statistical significance between the groups (P = .388). Conclusion: The results suggest that PRP application during arthroscopic rotator cuff repair did not clearly demonstrate accelerated recovery clinically or anatomically except for an improvement in internal rotation. Nevertheless, as the study may have been underpowered to detect clinically important differences in the structural integrity, additional investigations, including the optimization of PRP preparation and a larger randomized study powered for healing rate, are necessary to further determine the effect of PRP.
引用
收藏
页码:2082 / 2090
页数:9
相关论文
共 49 条
[1]
Platelet-rich plasma stimulates porcine articular chondrocyte proliferation and matrix biosynthesis [J].
Akeda, K. ;
An, H. S. ;
Okuma, M. ;
Attawia, M. ;
Miyamoto, K. ;
Thonar, E. J-M. A. ;
Lenz, M. E. ;
Sah, R. L. ;
Masuda, K. .
OSTEOARTHRITIS AND CARTILAGE, 2006, 14 (12) :1272-1280
[2]
Arthroscopic repair of full-thickness tears of the supraspinatus: Does the tendon really heal? [J].
Boileau, P ;
Brassart, N ;
Watkinson, DJ ;
Carles, M ;
Hatzidakis, AM ;
Krishnan, SG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (06) :1229-1240
[3]
BORDER WA, 1994, NEW ENGL J MED, V331, P1286
[4]
Arthroscopic rotator cuff repair: Analysis of results by tear size and by repair technique - Margin convergence versus direct tendon-to-bone repair [J].
Burkhart, SS ;
Danaceau, SM ;
Pearce, CE .
ARTHROSCOPY, 2001, 17 (09) :905-912
[5]
Functional efficacy of tendon kepair processes [J].
Butler, DL ;
Juncosa, N ;
Dressler, MR .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2004, 6 :303-329
[6]
Expression of insulin-like growth factor binding proteins in healing tendon lesions [J].
Dahlgren, LA ;
Mohammed, HO ;
Nixon, AJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (02) :183-192
[7]
Temporal expression of growth factors and matrix molecules in healing tendon lesions [J].
Dahlgren, LA ;
Mohammed, HO ;
Nixon, AJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (01) :84-92
[8]
Can platelet-rich plasma enhance tendon repair? A cell culture study [J].
de Mos, Marieke ;
van der Windt, Anna E. ;
Jahr, Holger ;
van Schie, Hans T. M. ;
Weinans, Harrie ;
Verhaar, Jan A. N. ;
van Osch, Gerjo J. V. M. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2008, 36 (06) :1171-1178
[9]
RESULTS OF A 2ND ATTEMPT AT SURGICAL REPAIR OF A FAILED INITIAL ROTATOR-CUFF REPAIR [J].
DEORIO, JK ;
COFIELD, RH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (04) :563-567
[10]
Dohan David M, 2006, Oral Surg Oral Med Oral Pathol Oral Radiol Endod, V101, pe45, DOI 10.1016/j.tripleo.2005.07.009