Robotic guidance for percutaneous interventions

被引:27
作者
Kronreif, G [1 ]
Fürst, M
Kettenbach, J
Figl, M
Hanel, R
机构
[1] ARC Seibersdorf Res, Mechatron Automat Syst, A-2444 Seibersdorf, Austria
[2] Univ Vienna, Sch Med, Dept Diagnost Radiol, Div Angiog & Intervent Radiol, A-1090 Vienna, Austria
[3] Univ Vienna, Dept Biomed Engn & Phys, A-1090 Vienna, Austria
关键词
image-guided intervention; computer-aided surgery; medical robotics; interventional radiology; biopsy;
D O I
10.1163/15685530360675532
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
A robotic system is being developed by ARC Seibersdorf Research in cooperation with the Departments of Biomedical Engineering and Physics as well as Diagnostic Radiology (both located at the Vienna University Hospital) in order to assist interventional radiologists when they are doing ultrasound (US)- or computed tomography (CT)-guided biopsies. According to the requirements from clinical practice, the complete system is mounted on a mobile platform and uses video I/O as a standardized interface to the various CT and US devices in practical use. During planning of the intervention, the interventionalist can use the US or CT scans acquired before to select the skin entry point as well as the target point. After confirmation of the planning, the robot is moved to the start position using different modes of motion. Finally, the needle is manually inserted by the interventionalist. The complete intervention can be monitored and documented by means of superimposed information of the planned and real biopsy trajectory on the actual CT or US scan. A feasibility study making use of a dedicated custom-made robotic system is aimed to validate the elaborated concept. The paper describes the developed arm and the controller architecture, and gives some first results from a pre-clinical test using a needle-penetrable medical phantom.
引用
收藏
页码:541 / 560
页数:20
相关论文
共 14 条
[1]   A new vacuum device for extremity immobilization [J].
Bale, RJ ;
Vogele, M ;
Rieger, M ;
Buchberger, W ;
Lukas, P ;
Jaschke, W .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) :1093-1094
[2]  
CLEARY K, 2002, P MED IM 2002 SAN DI, P25
[3]  
CLEARY K, 2001, P 15 INT C COMP AID, P171
[4]   3D ULTRASONIC IMAGE FEATURE LOCALIZATION BASED ON MAGNETIC SCANHEAD TRACKING - IN-VITRO CALIBRATION AND VALIDATION [J].
DETMER, PR ;
BASHEIN, G ;
HODGES, T ;
BEACH, KW ;
FILER, EP ;
BURNS, DH ;
STRANDNESS, DE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (09) :923-936
[5]  
GROGER M, 2002, P MED IM 2002 SAN DI, P233
[6]  
HEIGL E, 2001, PROTOTYP HOCHGENAUE
[7]  
HUMMEL J, 2002, THESIS U VIENNA
[8]   Radiation dosimetry at CT fluoroscopy: Physician's hand dose and development of needle holders [J].
Kato, R ;
Katada, K ;
Anno, H ;
Suzuki, S ;
Ida, Y ;
Koga, S .
RADIOLOGY, 1996, 201 (02) :576-578
[9]  
KRONREIF G, 2002, ARCP0025 ARCS
[10]  
Megali G, 2001, Medical Image Computing and Computer-Assisted Intervention-MICCAI, P343, DOI [10.1007/3-540-45468-3_41, DOI 10.1007/3-540-45468-3_41]