Comparison of potential solar electricity output from fixed-inclined and two-axis tracking photovoltaic modules in Europe

被引:46
作者
Huld, Thomas [1 ]
Suri, Marcel [1 ]
Dunlop, Ewan D. [1 ]
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Environm & Sustainabil, Renewable Energies Unit, I-21020 Ispra, Italy
来源
PROGRESS IN PHOTOVOLTAICS | 2008年 / 16卷 / 01期
关键词
photovoltaics; solar electricity; geographical information system; optimum inclination; two-axis tracking systems;
D O I
10.1002/pip.773
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
We present an approach to determine the potential energy gains of flat plate non-concentrating photovoltaic systems for the case of two-axis tracking and two inclination angles with fixed orientation (assuming biannual adjustment) compared to the configuration of single fixed optimum angle. The calculation is based on the Photovoltaic Geographic Information System (PVGIS), which integrates modelling tools with the pan-European solar radiation database. The results indicate that in the case of a PV system with two seasonal inclination angles, the maximum yearly gains, compared to the single fixed optimum angle, do not exceed 60-70 kWh per kW(p) in the Mediterranean region, while in the Baltic and North Sea regions this configuration gives less than 20 kWh extra. For the case of two-axis tracking, the relative energy gain compared to single fixed optimum angle is highest in the Northern latitudes but the absolute gain is much higher in the South. Typical yearly gains in Portugal and the Mediterranean region are in the range of 400-600 kWh per kW(p). The smallest absolute increase is found in the Northwest and Central Europe including the British Isles, where it is lower than 250 kWh per kW(p). For crystalline silicon we also investigate the effects of temperature and shallow-angle reflectivity on the comparison between fixed and tracking systems. While both effects reduce the overall energy output, the temperature degradation is stronger for tracking systems while the reflectivity reduces output more for fixed systems. The combined effect is almost equal for fixed and two-axis tracking systems. Copyright (C) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:47 / 59
页数:13
相关论文
共 12 条
  • [1] Site dependence of the energy collection of PV modules
    Bucher, K
    [J]. SOLAR ENERGY MATERIALS AND SOLAR CELLS, 1997, 47 (1-4) : 85 - 94
  • [2] Huld T, 2005, P 31 IEEE PHOT SPEC
  • [3] Estimating average daytime and daily temperature profiles within Europe
    Huld, Thomas A.
    Suri, Marcel
    Dunlop, Ewan D.
    Micale, Fabio
    [J]. ENVIRONMENTAL MODELLING & SOFTWARE, 2006, 21 (12) : 1650 - 1661
  • [4] JAHN U, 2004, P 19 EUR PHOT SOL EN, P2813
  • [5] KENNY R, 2003, P 3 WORLD C PHOT EN
  • [6] A practical method for the energy rating of c-Si CVW photovoltaic modules based on standard tests
    Kenny, RP
    Dunlop, ED
    Ossenbrink, HA
    Müllejans, H
    [J]. PROGRESS IN PHOTOVOLTAICS, 2006, 14 (02): : 155 - 166
  • [7] KENNY RP, 2006, P 21 EUR PHOT SOL EN
  • [8] Calculation of the PV modules angular losses under field conditions by means of an analytical model
    Martin, N
    Ruiz, JM
    [J]. SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2001, 70 (01) : 25 - 38
  • [9] Neteler M., 2002, OPEN SOURCE GIS GRAS
  • [10] REMUND J, 2003, P ISES SOL WORLD C S