Functional magnetic resonance imaging in intact plants -: Quantitative observation of flow in plant vessels

被引:23
作者
Kuchenbrod, E [1 ]
Kahler, E [1 ]
Thürmer, F [1 ]
Deichmann, R [1 ]
Zimmermann, U [1 ]
Haase, A [1 ]
机构
[1] Univ Wurzburg, Lehrstuhl Biophys, Inst Phys, D-97074 Wurzburg, Germany
关键词
magnetic resonance microscopy; flow velocity; MR contrast agents; MR in plants;
D O I
10.1016/S0730-725X(97)00307-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative magnetic resonance (MR) images of flow velocities in intact corn plants were acquired using magnetization-prepared MR microscopy. A phase contrast flow imaging technique was used to quantitate water how velocities and total volume flow rates in small xylem vessels. The simultaneous measurement of the transpiration of the whole plant was achieved by using a closed climate chamber within the MR magnet. The total volume flow rate and the transpiration values were in close correlation. Functional magnetic resonance imaging in intact plants was performed by light stimulation of the transpiration inside of the magnet. The change in the flow velocities in the xylem vessels of single vascular bundles was in correlation with the changes in the transpiration. Significant differences were observed between the xylem vessels in different vascular bundles. Furthermore, flow velocity measurements were performed on excised plant stems and visualized by the uptake of the MR contrast agent, gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA). A comparison between the phase contrast flow imaging and the contrast media uptake showed to be in good agreement with each other. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:331 / 338
页数:8
相关论文
共 14 条
[1]   BLOOD-FLOW EFFECTS IN MAGNETIC-RESONANCE IMAGING [J].
AXEL, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1157-1166
[2]   QUANTITATIVE IMAGING OF SLOW COHERENT MOTION BY STIMULATED ECHOES WITH SUPPRESSION OF STATIONARY WATER SIGNAL [J].
BOURGEOIS, D ;
DECORPS, M .
JOURNAL OF MAGNETIC RESONANCE, 1991, 94 (01) :20-33
[3]   USE OF DIFFERENCE PROPAGATORS FOR IMAGING OF CAPILLARY-FLOW IN THE PRESENCE OF STATIONARY FLUID [J].
CALLAGHAN, PT ;
KOCKENBERGER, W ;
POPE, JM .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 104 (02) :183-188
[4]   VELOCITY AND DIFFUSION IMAGING IN DYNAMIC NMR MICROSCOPY [J].
CALLAGHAN, PT ;
XIA, Y .
JOURNAL OF MAGNETIC RESONANCE, 1991, 91 (02) :326-352
[5]   FLOW MEASUREMENTS BY NMR [J].
CAPRIHAN, A ;
FUKUSHIMA, E .
PHYSICS REPORTS-REVIEW SECTION OF PHYSICS LETTERS, 1990, 198 (04) :195-235
[6]   MAGNETIZATION-PREPARED NMR MICROSCOPY [J].
HAASE, A ;
BRANDL, M ;
KUCHENBROD, E ;
LINK, A .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 105 (02) :230-233
[7]   CIRCULATION OF WATER WITHIN WHEAT-GRAIN REVEALED BY NUCLEAR MAGNETIC-RESONANCE MICRO-IMAGING [J].
JENNER, CF ;
XIA, Y ;
ECCLES, CD ;
CALLAGHAN, PT .
NATURE, 1988, 336 (6197) :399-402
[8]   A non-invasive measurement of phloem and xylem water flow in castor bean seedlings by nuclear magnetic resonance microimaging [J].
Kockenberger, W ;
Pope, JM ;
Xia, Y ;
Jeffrey, KR ;
Komor, E ;
Callaghan, PT .
PLANTA, 1997, 201 (01) :53-63
[9]   QUANTITATIVE NMR MICROSCOPY ON INTACT PLANTS [J].
KUCHENBROD, E ;
HAASE, A ;
BENKERT, R ;
SCHNEIDER, H ;
ZIMMERMANN, U .
MAGNETIC RESONANCE IMAGING, 1995, 13 (03) :447-455
[10]   Measurement of water flow in the xylem vessels of intact maize plants using flow-sensitive NMR imaging [J].
Kuchenbrod, E ;
Landeck, M ;
Thurmer, F ;
Haase, A ;
Zimmermann, U .
BOTANICA ACTA, 1996, 109 (03) :184-186