Automated high-throughput infusion ESI-MS with direct coupling to a microtiter plate

被引:27
作者
Felten, C
Foret, F
Minarik, M
Goetzinger, W
Karger, BL [1 ]
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
[2] Northeastern Univ, Dept Chem, Boston, MA 02115 USA
[3] ArQule, Woburn, MA 01801 USA
关键词
D O I
10.1021/ac001074w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the design and application of instrumentation for automated high-throughput infusion ESI-mass spectrometry, The approach, based on a subatmospheric ESI interface, allows sample introduction from a commercially available microtiter plate without the need for a separate fluid delivery system. The microtiter plate was placed vertically on a three-dimensional translation stage in front of the sampling ESI interface. A single, 7-cm, 20-mum-i.d. fused-silica capillary (total volume, 70 nL), with a tapered tip, served as a combination of sample delivery and spraying capillary. The tapered tip of the capillary was enclosed in a subatmospheric chamber attached in front of the orifice of the mass spectrometer. The sample aspiration rate (flow rate) was regulated by computer-controlled pneumatic valves, which allowed fast switching of the pressure in the subatmospheric ESI chamber. A flow-through wash device was positioned between the microtiter plate and the ESI interface. This design allowed alternate filling of the capillary with (a) sample from the wells and (b) wash solution from the wash device. Sample turnaround times of 10 s/sample, with a 120-nL sample consumption/analysis, and a duty cycle (percentage of total analysis time spent acquiring data) of 40% were achieved, The infusion system was demonstrated in the analysis of preparative HPLC fractions from a small molecule combinatorial library.
引用
收藏
页码:1449 / 1454
页数:6
相关论文
共 23 条
[1]  
Aubagnac JL, 1999, COMB CHEM HIGH T SCR, V2, P289
[2]   A high-throughput screening method for the determination of aqueous drug solubility using laser nephelometry in microtiter plates [J].
Bevan, CD ;
Lloyd, RS .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1781-1787
[3]  
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.3.CO
[4]  
2-S
[5]  
Caldwell GW, 1999, COMB CHEM HIGH T SCR, V2, P39
[6]  
De Bellis G, 2000, RAPID COMMUN MASS SP, V14, P243, DOI 10.1002/(SICI)1097-0231(20000229)14:4<243::AID-RCM870>3.0.CO
[7]  
2-F
[8]  
Fang AS, 1998, COMB CHEM HIGH T SCR, V1, P23
[9]  
FELTEN C, 1999, 47 ASMS C MASS SPECT
[10]   A novel nonmetallized tip for electrospray mass spectrometry at nanoliter flow rate [J].
Fong, KWY ;
Chan, TWD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (01) :72-75