A new method of measuring heparin levels in whole blood by protamine titration using a heparin-responsive electrochemical sensor

被引:29
作者
Wahr, JA
Yun, JH
Yang, VC
Lee, LM
Meyerhoff, ME
机构
[1] UNIV MICHIGAN HOSP,DEPT PHARMACEUT,ANN ARBOR,MI 48109
[2] UNIV MICHIGAN HOSP,DEPT CHEM,ANN ARBOR,MI 48109
关键词
anticoagulation; heparin concentration; hemostasis; potentiometric sensors;
D O I
10.1016/S1053-0770(05)80002-3
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To determine the ability of a new electrochemical sensor to determine heparin levels in whole blood and to correlate the heparin levels as determined by this heparin-responsive sensor (HRS) with heparin levels as determined by the Hepcon assay system (Medtronic Hemotec, Parker, CO). Design: Methods comparison study. Setting: A large academic medical center. Interventions: The heparin levels of 162 samples from 24 patients undergoing cardiopulmonary bypass were determined by the HRS system and by the Hepcon system. In 21 samples, heparin levels as measured by anti-Xa activity were determined as well. Measurements and Main Results; HRS-determined values correlated highly with Hepcon-determined values (r = 0.942) and with anti-Xa determined values (r = 0.905). Bias +/- precision comparing the HRS and Hepcon methods was 0.211 +/- 0.478 U/mL. Conclusions: HRS determined that whole blood heparin levels correlate well with Hepcon-determined levels. These limited results indicate that further development and testing of this new technology are warranted. Copyright (C) 1996 by W.B. Saunders Company
引用
收藏
页码:447 / 450
页数:4
相关论文
共 13 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
BULL BS, 1975, J THORAC CARDIOV SUR, V69, P685
[3]   COMPARISON OF ACTIVATED COAGULATION LIME AND WHOLE-BLOOD HEPARIN MEASUREMENTS WITH LABORATORY PLASMA ANTI-XA HEPARIN CONCENTRATION IN PATIENTS HAVING CARDIAC OPERATIONS [J].
DESPOTIS, GJ ;
SUMMERFIELD, AL ;
JOIST, JH ;
GOODNOUGH, LT ;
SANTORO, SA ;
SPITZNAGEL, E ;
COX, JL ;
LAPPAS, DG .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 108 (06) :1076-1082
[4]  
DIETRICH W, 1991, J THORAC CARDIOV SUR, V102, P505
[5]  
GRAVLEE GP, 1990, J THORAC CARDIOV SUR, V99, P518
[6]  
HORNE MK, 1989, BLOOD, V74, P238
[7]   ELECTROCHEMICAL SENSOR FOR HEPARIN - FURTHER CHARACTERIZATION AND BIOANALYTICAL APPLICATIONS [J].
MA, SC ;
YANG, VC ;
FU, B ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1993, 65 (15) :2078-2084
[8]   HEPARIN-RESPONSIVE ELECTROCHEMICAL SENSOR - A PRELIMINARY-STUDY [J].
MA, SC ;
YANG, VC ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1992, 64 (06) :694-697
[9]  
MEYERHOFF ME, 1995, CLIN CHEM, V41, P1355
[10]   CHARACTERIZATION OF PROTHROMBIN ACTIVATION DURING CARDIAC-SURGERY BY HEMOSTATIC MOLECULAR MARKERS [J].
SLAUGHTER, TF ;
LEBLEU, TH ;
DOUGLAS, JM ;
LESLIE, JB ;
PARKER, JK ;
GREENBERG, CS .
ANESTHESIOLOGY, 1994, 80 (03) :520-526