Light transport in tissue by 3D Monte Carlo:: Influence of boundary voxelization

被引:42
作者
Binzoni, T. [1 ,2 ]
Leung, T. S. [3 ]
Giust, R. [4 ]
Ruefenach, D.
Gandjbakhche, A. H. [5 ]
机构
[1] Univ Geneva, Ctr Med Univ Geneva, Dept Neurosci Fondamentales, CH-1211 Geneva, Switzerland
[2] Univ Hosp Geneva, Dept Image Sci Informat med, Geneva, Switzerland
[3] UCL, Dept Med Phys & Bioengn, London, England
[4] Univ Franche Comte, Inst FEMTO ST, Dept Opt PM Duffieux, CNRS,UMR 6174, F-25030 Besancon, France
[5] NICHHD, NIH, Lab Integrat & Med Biophys, Bethesda, MD 20892 USA
关键词
biomedical optics; Monte Carlo; photon transport; tissue phantom; voxels;
D O I
10.1016/j.cmpb.2007.10.008
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Monte Carlo (MC) based simulations of photon transport in living tissues have become the "gold standard" technique in biomedical optics. Three-dimensional (3D) voxel-based images are the natural way to represent human (and animal) tissues. It is generally believed that the combination of 3D images and MC based algorithms allows one to produce the most realistic models of photon propagation. In the present work, it is shown that this approach may lead to large errors in the MC data due to the "roughness" of the geometrical boundaries generated by the presence of the voxels. In particular, the computed intensity of the light detected on the tissue surface of a simple cubic tissue phantom may display errors from -80% to 120%. It is also shown that these errors depend in a complex manner on optical and geometrical parameters such as the interoptode distance, scattering coefficient, refractive index, etc. and on the degree of voxelization ("roughness") of the boundaries. It is concluded that if one wants to perform reliable 3D Monte Carlo simulations on complex geometries, such as human brain, skin or trabecular bone, it is necessary to introduce boundary meshing techniques or other equivalent procedures in the MC code to eliminate the deleterious effect of voxelization. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:14 / 23
页数:10
相关论文
共 36 条
[1]  
[Anonymous], P SPIE IS
[2]   Optical imaging in medicine .2. Modelling and reconstruction [J].
Arridge, SR ;
Hebden, JC .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (05) :841-853
[3]   THE THEORETICAL BASIS FOR THE DETERMINATION OF OPTICAL PATHLENGTHS IN TISSUE - TEMPORAL AND FREQUENCY-ANALYSIS [J].
ARRIDGE, SR ;
COPE, M ;
DELPY, DT .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (07) :1531-1560
[4]   A physiological model of cerebral blood flow control [J].
Banaji, M ;
Tachtsidis, A ;
Delpy, D ;
Baigent, S .
MATHEMATICAL BIOSCIENCES, 2005, 194 (02) :125-173
[5]   Optical Monte Carlo modeling of a true port wine stain anatomy [J].
Barton, JK ;
Pfefer, TJ ;
Welch, AJ ;
Smithies, DJ ;
Nelson, JS ;
van Gemert, MJC .
OPTICS EXPRESS, 1998, 2 (09) :391-396
[6]   Strategies for the physiome project [J].
Bassingthwaighte, JB .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (08) :1043-1058
[7]   The optical properties of lung as a function of respiration [J].
Beek, JF ;
vanStaveren, HJ ;
Posthumus, P ;
Sterenborg, HJCM ;
vanGemert, MJC .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2263-2272
[8]   Muscle O2 consumption by NIRS:: a theoretical model [J].
Binzoni, T ;
Colier, W ;
Hiltbrand, E ;
Hoofd, L ;
Cerretelli, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (02) :683-688
[9]   Three dimensional Monte Carlo code for photon migration through complex heterogeneous media including the adult human head [J].
Boas, DA ;
Culver, JP ;
Stott, JJ ;
Dunn, AK .
OPTICS EXPRESS, 2002, 10 (03) :159-170
[10]   Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging [J].
Briers, JD .
PHYSIOLOGICAL MEASUREMENT, 2001, 22 (04) :R35-R66