Phase system selectivity and two-dimensional separations in liquid column chromatography

被引:34
作者
Jandera, P [1 ]
Halama, M [1 ]
Kolárová, L [1 ]
Fischer, J [1 ]
Novotná, K [1 ]
机构
[1] Univ Pardubice, Dept Analyt Chem, Pardubice 53210, Czech Republic
关键词
column liquid chromatography; two-dimensional separations; phase system selectivity; peak capacity; ethylene oxide-propylene oxide (co)oligomers; triacylglycerols; REVERSED-PHASE; STATISTICAL-THEORY; MASS-SPECTROMETRY; COMPLEX-MIXTURES; SPOT OVERLAP; TRIACYLGLYCEROL; INSTRUMENTATION; PREDICTION; OLIGOMERS; ELUTION;
D O I
10.1016/j.chroma.2005.01.061
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Correlations between the separation selectivity in aqueous and non-aqueous reversed-phase systems and in normal-phase LC systems were investigated for samples containing different numbers of two repeat structural elements. Such samples are best separated in "orthogonal" two-dimensional chromatographic systems, showing selectivity for one type of the repeat structural element only in the first dimension and for the other structural element only in the second dimension. The number of resolved compounds improves as the degree of orthogonality of the separation systems increases with decreasing correlation between the selectivities for the sample structural distribution in the two dimensions. Orthogonal systems with non-correlated selectivities for each repeat structural element provide the highest number of separated peaks and regular arrangement of the peaks over the two-dimensional retention space according to the individual structural element distribution and the best use of the available peak capacity. Fully orthogonal systems are difficult to find in practice. Partially orthogonal system with correlated selectivities for one structural type distribution, but with one system non-distinguishing the distribution for the other structural element are still useful for the two-dimensional separations. The correlations between the selectivities for repeat regular structural increments were employed to evaluate the suitability of phase systems for two-dimensional HPLC separations. The selectivity correlation in various reversed-phase and normal-phase systems was evaluated for two sample types: (1) Various RP columns show significantly inversely correlated selectivities for acyl lengths and numbers of double bonds distribution, but the differences in the double bond selectivity can be used for practical separations of triacylglycerols with the same equivalent carbon numbers. (2) Synthetic EO-PO block (co)oligomers with two-dimensional distribution of oxyethylene and oxypropylene monomer units were separated according to the two distribution types using on-line two-dimensional reversed-phase-normal-phase LC with a C18 column in the first dimension and an aminopropyl silica column in the second dimension. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:112 / 123
页数:12
相关论文
共 40 条
[1]  
Bertsch W, 1999, HRC-J HIGH RES CHROM, V22, P647, DOI 10.1002/(SICI)1521-4168(19991201)22:12<647::AID-JHRC647>3.0.CO
[2]  
2-V
[3]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[4]   Recent advances in liquid chromatography analysis of synthetic polymers [J].
Chang, TY .
LIQUID CHROMATOGRAPHY FTIR MICROSPECTROSCOPY MICROWAVE ASSISTED SYNTHESIS, 2003, 163 :1-60
[5]   STATISTICAL-THEORY OF SPOT OVERLAP FOR N-DIMENSIONAL SEPARATIONS [J].
DAVIS, JM .
ANALYTICAL CHEMISTRY, 1993, 65 (15) :2014-2023
[6]   STATISTICAL-THEORY OF SPOT OVERLAP IN 2-DIMENSIONAL SEPARATIONS [J].
DAVIS, JM .
ANALYTICAL CHEMISTRY, 1991, 63 (19) :2141-2152
[7]   Prediction of numbers of singlets, doublets, and triplets in poorly resolved separations by statistical-overlap theory [J].
Davis, JM .
JOURNAL OF CHROMATOGRAPHY A, 1999, 831 (01) :37-49
[8]  
DAVIS JM, 1983, ANAL CHEM, V55, P418, DOI 10.1021/ac00254a003
[9]   Off-line coupling of non-aqueous reversed-phase and silver ion high-performance liquid chromatography-mass spectrometry for the characterization of rice oil triacylglycerol positional isomers [J].
Dugo, P ;
Favoino, O ;
Tranchida, PQ ;
Dugo, G ;
Mondello, L .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1041 (1-2) :135-142
[10]   2-DIMENSIONAL COLUMN LIQUID-CHROMATOGRAPHIC TECHNIQUE FOR RESOLUTION OF COMPLEX-MIXTURES [J].
ERNI, F ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1978, 149 (FEB) :561-569