Preliminary results of endovascular abdominal aortic aneurysm exclusion with the AneuRx stent-graft

被引:32
作者
Howell, MH
Strickman, N
Mortazavi, A
Hallman, CH
Krajcer, Z
机构
[1] St Lukes Episcopal Hosp, Texas Heart Inst, Dept Cardiovasc Surg, Houston, TX USA
[2] St Lukes Episcopal Hosp, Texas Heart Inst, Dept Cardiol, Houston, TX USA
关键词
D O I
10.1016/S0735-1097(01)01495-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study evaluated the clinical effectiveness of the Medtronic AneuRx stent-graft in patients with infrarenal abdominal aortic aneurysms (AAAs) who were treated in an endovascular suite. BACKGROUND The use of endovascular stent-graft prosthesis for the treatment of AAAs is receiving increasing attention as an alternative to standard surgical repair. Endovascular treatment of AAAs offers the potential to avoid the significant morbidity and mortality associated with surgical repair. METHODS In this series, 215 patients have undergone AAA exclusion with the AneuRx stent-graft. Six-month follow-up is available in 132 patients; one-year follow-up is available in 84 and two-year follow-up in 22. RESULTS Of the patients, one hundred ninety-two (89%) were male; 87% had hypertension, and 58.6% were American Society of Anesthesiologists grade IV or higher. The procedural success was 99.5%; we were una lc to place the, device in one patient. There was no procedural or one-month mortality. There were no acute conversions to surgical repair. One patient had a non-Q-wave myocardial infarction 24 h after the procedure. Endoleaks were present in 82 patients (42%) at discharge, 15 patients (11.3%) at six months and 10 patients (11.9%) at one year. Twenty-two patients had a secondary procedure for endoleak repair of which three, were conversions to surgical repair. Twelve late deaths have occurred, none due to device failure or AAA,rupture. Mean hospital stay was 1.9 days. CONCLUSIONS These results reveal that infrarenal AAAs can be safely and successfully treated in an endovascular suite with the AneuRx stent-graft. Further follow-up is needed to determine the long-term efficacy of endoluminal treatment to prevent rupture and death due to AAAs. (C) 2001 by the American College of Cardiology.
引用
收藏
页码:1040 / 1046
页数:7
相关论文
共 36 条
[1]   Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms [J].
Blum, U ;
Voshage, G ;
Lammer, J ;
Beyersdorf, F ;
Tollner, D ;
Kretschmer, G ;
Spillner, G ;
Polterauer, P ;
Nagel, G ;
Holzenbein, T ;
Thurnher, S ;
Langer, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (01) :13-20
[2]  
Blum U, 1997, J ENDOVASC SURG, V4, P137, DOI 10.1583/1074-6218(1997)004<0137:TCGEWA>2.0.CO
[3]  
2
[4]  
Chuter T A, 1995, Cardiovasc Surg, V3, P121, DOI 10.1016/0967-2109(95)90884-8
[5]   Clinical experience with a bifurcated endovascular graft for abdominal aortic aneurysm repair [J].
Chuter, TAM ;
Risberg, B ;
Hopkinson, BR ;
Wendt, G ;
Scott, RAP ;
Walker, PJ ;
Viscomi, S ;
White, G .
JOURNAL OF VASCULAR SURGERY, 1996, 24 (04) :655-666
[6]  
ERNST CB, 1993, NEW ENGL J MED, V328, P1167
[7]  
Görich J, 1999, J ENDOVASC SURG, V6, P136, DOI 10.1583/1074-6218(1999)006<0136:EROAAT>2.0.CO
[8]  
2
[9]  
Howell M, 2001, J ENDOVASC THER, V8, P68, DOI 10.1583/1545-1550(2001)008<0068:PAACOF>2.0.CO
[10]  
2