Linear and angular measurements of computer-generated models: Are they accurate, valid, and reliable?

被引:41
作者
Jamali, Amir A. [1 ]
Deuel, Christopher [1 ]
Perreira, Aimee [2 ]
Salgad, Christopher J. [3 ]
Hunter, John C. [4 ]
Strong, E. Bradley [5 ]
机构
[1] Univ Calif Davis, Med Ctr, Dept Orthopaed Surg, Sacramento, CA 95817 USA
[2] Univ Calif Davis, Sch Med, Davis, CA 95616 USA
[3] Univ Med & Dent New Jersey, Cooper Univ Hosp, Dept Plast Surg, Camden, NJ USA
[4] Univ Calif Davis, Dept Radiol, Sacramento, CA 95817 USA
[5] Univ Calif Davis, Dept Otolaryngol, Sacramento, CA 95817 USA
关键词
CT; computer-generated model; angular measurement; mimics; INTRACRANIAL VOLUME MEASUREMENTS; FEMOROACETABULAR IMPINGEMENT; CT SCANS; HIP; TOMOGRAPHY; CRANIOSYNOSTOSIS; OSTEOARTHRITIS; ARTHROPLASTY; KINEMATICS; CHILDHOOD;
D O I
10.1080/10929080701680265
中图分类号
R61 [外科手术学];
学科分类号
100210 [外科学];
摘要
Introduction: Traditional advanced imaging modalities such as CT and MRI are limited in their ability to perform accurate linear distance and angular measurements regardless of anatomical orientation. The construction of 3D models has been used to perform anthropornetric analyses as well as in the reconstruction of rapid prototypes. We hypothesized that such measurements would be precise to within 2mm or 2 degrees of measurements performed with a coordinate measurement machine (CMM). We also hypothesized that there would be a high degree of interobserver reliability with these measurements. Materials and Methods: Multiple aluminum screws were implanted in various positions in three foam pelvises which were subsequently scanned by CT and rendered as 3D models using a. commercially available software package (Mimics). Linear and angular measurements were performed using a CMM machine, the software package, and a dial caliper or goniometer. The deviation of the measurements from the CMM. data was compared using ANOVA. The interobserver reliability of both the manual and computer-generated measurements was calculated. Results: The mean difference between the CMM distances and those measured manually and with the software was 2.12 +/- 1.20mm and 1.57 +/- 1.05 mm, respectively. The mean difference between the CMM angular measurements and the angular measurements performed manually and with the software was 4.07 +/- 4.70 degrees and 1.62 +/- 1.32 degrees, respectively. In all cases, the manual measurements were significantly less accurate (p < 0.0001) and there was a high degree of interobserver reliability. Conclusions: Computer-generated measurements taken from three-dimensionally reconstructed models are more accurate than manual measurements and are within 2 mm and 2 degrees of measurements performed with a CMM. These measurements have high interobserver reliability.
引用
收藏
页码:278 / 285
页数:8
相关论文
共 28 条
[1]
OCCIPITOFRONTAL HEAD CIRCUMFERENCE - AN ACCURATE MEASURE OF INTRACRANIAL VOLUME [J].
BRAY, PF ;
SHIELDS, WD ;
WOLCOTT, GJ ;
MADSEN, JA .
JOURNAL OF PEDIATRICS, 1969, 75 (02) :303-&
[2]
VOLUME DETERMINATIONS USING COMPUTED-TOMOGRAPHY [J].
BREIMAN, RS ;
BECK, JW ;
KOROBKIN, M ;
GLENNY, R ;
AKWARI, OE ;
HEASTON, DK ;
MOORE, AV ;
RAM, PC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (02) :329-333
[3]
Brown G A, 2001, Iowa Orthop J, V21, P20
[4]
Rapid prototyping: The future of trauma surgery? [J].
Brown, GA ;
Firoozbakhsh, K ;
DeCoster, TA ;
Reyna, JR ;
Moneim, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :49-55
[5]
In vivo radiocarpal kinematics and the dart thrower's motion [J].
Crisco, JJ ;
Coburn, JC ;
Moore, DC ;
Akelman, E ;
Weiss, APC ;
Wolfe, SW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (12) :2729-2740
[6]
Femoroacetabular impingement -: A cause for osteoarthritis of the hip [J].
Ganz, R ;
Parvizi, J ;
Beck, M ;
Leunig, M ;
Nötzli, H ;
Siebenrock, KA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) :112-120
[7]
A STUDY OF INTRACRANIAL VOLUME IN APERT SYNDROME [J].
GOSAIN, AK ;
MCCARTHY, JG ;
GLATT, P ;
STAFFENBERG, D ;
HOFFMANN, RG .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1995, 95 (02) :284-295
[8]
VOLUMETRIC QUANTIFICATION OF BRAIN VOLUME IN CHILDREN USING SEQUENTIAL CT SCANS [J].
HAMANO, K ;
IWASAKI, N ;
KAWASHIMA, K ;
TAKITA, H .
NEURORADIOLOGY, 1990, 32 (04) :300-303
[9]
The influence of three-dimensional computed tomography reconstructions on the characterization and treatment of distal radial fractures [J].
Harness, Neil G. ;
Ring, David ;
Zurakowski, David ;
Harris, Gordon J. ;
Jupiter, Jesse B. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (06) :1315-1323
[10]
Acetabular fractures revisited: A new CT-based classification [J].
Harris, JH ;
Coupe, KJ ;
Lee, JS ;
Trotscher, T .
SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2005, 9 (02) :150-160