A system for protecting the environment from ionising radiation: selecting reference fauna and flora, and the possible dose models and environmental geometries that could be applied to them

被引:55
作者
Pentreath, RJ
Woodhead, DS
机构
[1] Univ Reading, Environm Syst Sci Ctr, Reading RG6 6AB, Berks, England
[2] CEFAS, Lowestoft Lab, Lowestoft NR33 0HT, Suffolk, England
关键词
ionising radiation; environmental protection; dose models;
D O I
10.1016/S0048-9697(01)00888-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In order to demonstrate. explicitly, that the environment can be protected with respect to controlled sources of ionising radiation, it is essential to have a systematic framework within which dosimetry models for fauna and flora can be used. And because of the practical limitations on what could reasonably be modelled and the amount of information that could reasonably be obtained. it is also necessary to limit the application of such models to a 'set' of fauna and flora within a 'reference' context. This paper, therefore, outlines the factors that will need to be considered to select such 'reference' fauna and flora, and describes some of the factors and constraints necessary to develop the associated dosimetry models. It also describes some of the most basic environmental geometries within which the dose models could be set in order to make comparisons amongst different radiation sources. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:33 / 43
页数:11
相关论文
共 31 条
[1]   A METHOD TO ASSESS ENVIRONMENTAL ACCEPTABILITY OF RELEASES OF RADIONUCLIDES FROM NUCLEAR-FACILITIES [J].
AMIRO, BD ;
ZACH, R .
ENVIRONMENT INTERNATIONAL, 1993, 19 (04) :341-358
[2]   Radiological dose conversion factors for generic non-human biota used for screening potential ecological impacts [J].
Amiro, BD .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1997, 35 (01) :37-51
[3]  
AMIRO BD, 1996, P INT S ION RAD
[4]  
[Anonymous], 1991, ANN ICRP, V60
[5]  
HETHERINGTON JA, 1976, ENV PUBLIC HLTH CONS, P139
[6]  
*IAEA, 1988, TECHN REP SER, V288
[7]  
*IAEA, 1998, RADIOLOGICAL SITUATI, V6
[8]  
*IAEA, 1976, TECHN REP SER, V172
[9]  
*IAEA, 1998, RADIOLOGICAL CONDITI
[10]  
*IAEA, 1979, TECHN REP SER, V190