Aims Electrical storm (ES) is a life -threatening arrhythmia complication affecting patients treated with an implantable cardioverter defibrillator (ICD). Despite its increasing importance, existing data on prognosis and management of ICD patients affected by ES are limited and conflicting. Methods We prospectively studied 169 consecutive patients receiving an ICD. Thirty-two patients presented with at least one episode of ES during the period of observation (33 +/- 26 months). ES patients were older (64 +/- 9 vs. 59 +/- 13 years, P=0.013) with more advanced congestive heart failure (CHF) but a similar incidence of an underlying organic heart disease. Results Long-term total and cardiac mortality were both increased among ES patients. Seventeen of the 32 ES patients died as opposed to 19 of the 137 ICD patients without ES (53 vs. 14%, P < 0.001). In multivariate Cox regression analysis adjusted for the main confounders, history of ES was significantly and independently associated with total and cardiac mortality (risk ratio (RR)=2.13, P=0.031 and RR=2.59, P=0.019, respectively). Conclusion ES is a relatively frequent complication affecting ICD patients treated for secondary prevention of sudden cardiac death (SCD). Although the acute management of this serious arrhythmia complication is usually successful, occurrence of ES is a strong independent predictor of poor outcome in ICD patients. (c) 2005 The European Society of Cardiology. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:184 / 192
页数:9
相关论文
共 38 条
[1]   RESULTS OF CORONARY-ARTERY SURGERY IN PATIENTS WITH POOR LEFT-VENTRICULAR FUNCTION (CASS) [J].
ALDERMAN, EL ;
FISHER, LD ;
LITWIN, P ;
KAISER, GC ;
MYERS, WO ;
MAYNARD, C ;
LEVINE, F ;
SCHLOSS, M .
CIRCULATION, 1983, 68 (04) :785-795
[2]   Cardiac troponin I levels are normal or minimally elevated after transthoracic cardioversion [J].
Allan, JJ ;
Feld, RD ;
Russell, AA ;
Ladenson, JH ;
Rogers, MAM ;
Kerber, RE ;
Jaffe, AS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (04) :1052-1056
[3]   AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR DISCHARGES AND ACUTE MYOCARDIAL INJURY [J].
AVITALL, B ;
PORT, S ;
GAL, R ;
MCKINNIE, J ;
TCHOU, P ;
JAZAYERI, M ;
TROUP, P ;
AKHTAR, M .
CIRCULATION, 1990, 81 (05) :1482-1487
[4]   SIGNAL-AVERAGED ELECTROCARDIOGRAPHY IN THE TIME AND FREQUENCY DOMAINS [J].
BUCKINGHAM, TA ;
THESSEN, CM ;
HERTWECK, D ;
JANOSIK, DL ;
KENNEDY, HL .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (12) :820-825
[5]   A randomized study of the prevention of sudden death in patients with coronary artery disease [J].
Buxton, AE ;
Lee, KL ;
Fisher, JD ;
Josephson, ME ;
Prystowsky, EN ;
Hafley, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (25) :1882-1890
[6]   Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. [J].
Cazeau, S ;
Leclercq, C ;
Lavergne, T ;
Walker, S ;
Varma, C ;
Linde, C ;
Garrigue, S ;
Kappenberger, L ;
Haywood, GA ;
Santini, M ;
Bailleul, C ;
Daubert, JC .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (12) :873-880
[7]   Near fatal electrical storm in a patient equipped with an implantable cardioverter defibrillator for Brugada syndrome [J].
Chalvidan, T ;
Deharo, JC ;
Dieuzaide, P ;
Defaye, P ;
Djiane, P .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (03) :410-412
[8]   Canadian implantable defibrillator study (CIDS) - A randomized trial of the implantable cardioverter defibrillator against amiodarone [J].
Connolly, SJ ;
Gent, M ;
Roberts, RS ;
Dorian, P ;
Roy, D ;
Sheldon, RS ;
Mitchell, LB ;
Green, MS ;
Klein, GJ ;
O'Brien, B .
CIRCULATION, 2000, 101 (11) :1297-1302
[9]   Electrical storm in patients with transvenous implantable cardioverter-defibrillators - Incidence, management and prognostic implications [J].
Credner, SC ;
Klingenheben, T ;
Mauss, O ;
Sticherling, C ;
Hohnloser, SH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (07) :1909-1915
[10]  
Dorian P, 1997, CAN J CARDIOL, V13, pA13