Three-dimensional gadolinium-enhanced MR angiography of the thoracic aorta

被引:182
作者
Prince, MR [1 ]
Narasimham, DL [1 ]
Jacoby, WT [1 ]
Williams, DM [1 ]
Cho, KJ [1 ]
Marx, MV [1 ]
Deeb, GM [1 ]
机构
[1] UNIV MICHIGAN, DEPT SURG, ANN ARBOR, MI 48109 USA
关键词
D O I
10.2214/ajr.166.6.8633452
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Our objective was to evaluate image quality and preliminary clinical experience with three-dimensional gadolinium-enhanced MR angiography of the thoracic aorta. SUBJECTS AND METHODS. Ninety patients with suspected thoracic aorta pathology underwent 97 MR examinations at 1.5 T with a 4-min, three-dimensional spoiled gradient-echo technique. Gadolinium infusion was timed for maximum arterial contrast during acquisition of the central portion of K-space. No ECG gating or breath-holding was used. All MR examinations were evaluated retrospectively for intravascular signal-to-noise ratio (SNR). In 30 of the 90 patients, results from surgery (n = 11), angiography (n = 12), or both (n = 7) were available. Four radiologists who were unaware of the angiographic or surgical findings assessed each of these 30 examinations for three types of pathology: dissection, coarctation, or aneurysm. The observers also assessed aortic branch vessel patency and vascular anomalies in the 19 patients who had angiographic correlation. RESULTS. Image quality (determined as SNR) was highest in the aortic arch, upper descending thoracic aorta, and upper abdominal aorta. We saw a small reduction in the SNR in the ascending aorta and lower descending thoracic aorta (p < .0001), attributable to cardiac and respiratory motion. Image quality was not affected by slow flow. MR imaging correctly diagnosed pathology in all 30 patients with angiographic or surgical correlation, including eight dissections, three coarctations, and 10 aneurysms. The type of dissection was correctly determined in all eight patients. Stenoses of major branch vessel origins were detected with a sensitivity of 90% (95% bayesian confidence interval, 99-63%) and a specificity of 96% (95% bayesian confidence interval, 99-89%) in the 19 patients with angiographic correlation. Five vascular anomalies, including an aberrant right subclavian artery, a bovine arch, and three accessory renal arteries, were correctly identified. CONCLUSION. Three-dimensional gadolinium-enhanced MR angiography has the potential to accurately diagnose aortic dissection, coarctation, and aneurysm. It does not require ECG gating or breath-holding and thereby extends the diagnostic utility of MR imaging for the thoracic aorta.
引用
收藏
页码:1387 / 1397
页数:11
相关论文
共 27 条
[1]   ASSESSMENT OF THE THORACIC AORTA BY SPIRAL CT [J].
COSTELLO, P ;
ECKER, CP ;
TELLO, R ;
HARTNELL, GG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (05) :1127-1130
[2]  
DEBAKEY ME, 1982, SURGERY, V92, P1118
[3]   TYPE-A DISSECTION OF THE THORACIC AORTA - USE OF MR-IMAGING FOR LONG-TERM FOLLOW-UP [J].
GAUBERT, JY ;
MOULIN, G ;
MESANA, T ;
CHAGNAUD, C ;
CAUS, T ;
DELANNOY, L ;
BLIN, D ;
BARTOLI, JM ;
KASBARIAN, M .
RADIOLOGY, 1995, 196 (02) :363-369
[4]   MR-IMAGING OF THE THORACIC AORTA - COMPARISON OF SPIN-ECHO, ANGIOGRAPHIC, AND BREATH-HOLD TECHNIQUES [J].
HARTNELL, GG ;
FINN, JP ;
ZENNI, M ;
COHEN, MC ;
DUPUY, DE ;
WHEELER, HG ;
LONGMAID, HE .
RADIOLOGY, 1994, 191 (03) :697-704
[5]   Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries [J].
Holland, GA ;
Dougherty, L ;
Carpenter, JP ;
Golden, MA ;
Gilfeather, M ;
Slossman, F ;
Schnall, MD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (04) :971-981
[6]   FATAL REACTION TO GADOPENTETATE DIMEGLUMINE [J].
JORDAN, RM ;
MINTZ, RD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (03) :743-744
[7]   MR-IMAGING (INCLUDING MR-ANGIOGRAPHY) OF ABDOMINAL AORTIC-ANEURYSMS - COMPARISON WITH CONVENTIONAL ANGIOGRAPHY [J].
KAUFMAN, JA ;
GELLER, SC ;
PETERSEN, MJ ;
CAMBRIA, RP ;
PRINCE, MR ;
WALTMAN, AC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (01) :203-210
[8]   AORTIC DISSECTION - SENSITIVITY AND SPECIFICITY OF MR IMAGING [J].
KERSTINGSOMMERHOFF, BA ;
HIGGINS, CB ;
WHITE, RD ;
SOMMERHOFF, CP ;
LIPTON, MJ .
RADIOLOGY, 1988, 166 (03) :651-655
[9]   3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY USING SELECTIVE INVERSION-RECOVERY RAGE WITH FAT-SATURATION AND ECG-TRIGGERING - APPLICATION TO RENAL-ARTERIES [J].
LI, D ;
HAACKE, EM ;
MUGLER, JP ;
BERR, S ;
BROOKEMAN, JR ;
HUTTON, MC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (04) :414-422
[10]   THE ROLE OF MR IMAGING IN THE EVALUATION OF ACQUIRED DISEASES OF THE THORACIC AORTA [J].
LINK, KM ;
LESKO, NM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (05) :1115-1125