The biaxial flexural strength of two pressable ceramic systems

被引:53
作者
Cattell, MJ
Knowles, JC
Clarke, RL
Lynch, E
机构
[1] St Bartholomews & Royal London Sch Med & Dent, QMW, Dept Conservat Dent, London E1 2AD, England
[2] UCL Eastman Dent Inst, Dept Biomat, London WC1 8LD, England
关键词
ceramics; bending stress; microscopy;
D O I
10.1016/S0300-5712(98)00047-5
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
The biaxial flexural strength of Optimal pressable ceramics and TPS Empress pressable ceramics were tested, compared and the microstructures and compositions explored. The materials evaluated were Optimal shaded (Opcs) and unshaded (Opcus) ceramics and IFS Empress shaded (Ems) and unshaded (Emus) ceramics. Twenty-one disc specimens per material were prepared, heat-treated and tested. The piston on three-ball test ASTM F394-78 (1991) was used to test the specimens in a universal testing machine at a crosshead speed of 0.15 mm/min. Specimens were viewed in a scanning electron microscope and X-ray diffraction used to determine the phases present. Mean strengths (MPa +/- SD) were: Ems 120.1 +/- 20.5, Emus 135.8 +/- 16.0, Opcs 139.1 +/- 14.3 and Opcus 138.0 +/- 11.5. Then was no statistically significant difference between Optimal shaded, Optimal unshaded and Empress unshaded strength values (p > 0.05). Empress shaded strength values were significantly lower than the other materials tested (p < 0.05). Weibull analysis provided m values: Ems 6.1, Emus 10.2, Opcs 12.8 and Opcus 13.9 and 1% and 5% probabilities of failure. Secondary electron imaging revealed a dense dispersal of leucite crystals in the glassy matrix of the Optimal ceramics of an average size 5.5 +/- 9.7 mu m(2) for the Optimal shaded ceramic and 6.6 +/- 13.3 mu m(2) for the Optimal unshaded ceramic. Leucite crystal agglomerates were evident for the Empress shaded material and a uniform distribution of fine leucite crystals (1.9 +/- 1.8 mu m(2)) for the Empress unshaded ceramic. Crystal and matrix microcracking were present in most of the material microstructures, together with porosity and tabular alumina platelets in the Optimal ceramics. X-ray diffraction revealed the presence of tetragonal leucite and small amounts of cubic leucite. Optimal ceramics and Empress unshaded ceramic provided higher strength and Weibull in values compared with Empress shaded ceramic. Inherent material defects were characterised and cubic leucite was identified. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:183 / 196
页数:14
相关论文
共 27 条
[1]
[Anonymous], 1991, F39478 ASTM, P424
[2]
*ASTM, 1995, C1239 ASTM, P359
[3]
INFLUENCE OF TEST METHOD ON FAILURE STRESS OF BRITTLE DENTAL MATERIALS [J].
BAN, S ;
ANUSAVICE, KJ .
JOURNAL OF DENTAL RESEARCH, 1990, 69 (12) :1791-1799
[4]
BEHAM G, 1990, IVOCLAR VIVADENT REP, V6, P1
[5]
The transverse strength, reliability and microstructural features of four dental ceramics .1. [J].
Cattell, MJ ;
Clarke, RL ;
Lynch, EJR .
JOURNAL OF DENTISTRY, 1997, 25 (05) :399-407
[6]
The Strength of Two-Phase Ceramic/Glass Materials [J].
Davidge, R. W. ;
Green, T. J. .
JOURNAL OF MATERIALS SCIENCE, 1968, 3 (06) :629-634
[7]
DENRY IL, 1996, J DENT RES, V75, P928
[8]
DOVE MT, 1993, AM MINERAL, V78, P486
[9]
THE EFFECT OF GLAZE ON PORCELAIN STRENGTH [J].
FAIRHURST, CW ;
LOCKWOOD, PE ;
RINGLE, RD ;
THOMPSON, WO .
DENTAL MATERIALS, 1992, 8 (03) :203-207
[10]