Evaluation of near-surface soil moisture data from an AAFC monitoring network in Manitoba, Canada: Implications for L-band satellite validation

被引:39
作者
Adams, Justin R. [1 ,2 ]
McNairn, Heather [2 ]
Berg, Aaron A. [1 ]
Champagne, Catherine [2 ]
机构
[1] Univ Guelph, Dept Geog, Guelph, ON N1G 2W1, Canada
[2] Agr & Agri Food Canada, Sci & Technol Branch, Ottawa, ON K1A 0C6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Soil moisture; Remote sensing; In-situ networks; WATER CONTENT VARIABILITY; SMOS DATA; CALIBRATION; PRODUCTS;
D O I
10.1016/j.jhydrol.2014.10.024
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper examines near-surface soil moisture data (top similar to 6 cm) from an Agriculture and Agri-food Canada (AAFC) monitoring network in southern Manitoba, Canada, over the 2012 and 2013 growing seasons. This network is intended for use (in part) as a core validation site for the Soil Moisture Active Passive (SMAP) mission. The network currently consists of 9 stations sited within agricultural fields. Each station uses a triplicate configuration of horizontally installed Hydra Probe soil moisture sensors at near-surface (similar to 5 an) to root-zone soil depths, in addition to permanently installed vertical surface sensors (0-5.7 cm). This domain was studied intensively over the 6.5 week SMAPVEX12 ground campaign in June/July 2012, providing coincident soil moisture datasets to assess network up-scaling over the domain. Results demonstrate that statistical differences exist between the network-level data from the horizontal (theta(3.5-6.5cm)) and vertical (theta(0-5.7cm)) surface Hydra Probes over 2012-13. Bootstrap resampling shows that a mean difference of 0.018 m(3) m(-3) (at 99% confidence) is observed between theta(3.5-6.5cm) and theta(0-5.7cm) measurement depths (theta(0-5.7cm) sensors exhibit dry bias). Individual station analysis shows that the largest differences between theta(3.5-6.5cm) and theta(0-5.7cm) measurement depth occur at sites with higher clay content, whereas sensors located in sandy soils exhibit negligible differences. Up-scaling comparisons of the AAFC network to field-sampled data and a dense temporary network over SMAPVEX12 demonstrate that it is representative of the domain within 0.04 m(3) m(-3) RMSE. This suggests that the AAFC network is suitable for coarse resolution L-band microwave soil moisture validation. Comparison of Soil Moisture Ocean Salinity (SMOS) Level 2 soil moisture product data to the up-scaled AAFC network data over 2012-13 shows that superior temporal correlation is found with the theta(0-5.7cm) dataset. The difference in RMSEs between the SMOS comparisons to theta(3.5-6.5cm) and theta(0-5.7cm) network datasets is approximately 0.018 m(3) m(-3). These results suggest that differences of near-surface measurement depth and sensor configuration should be considered when conducting L-band satellite validation. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:582 / 592
页数:11
相关论文
共 60 条
[1]   Field Level Soil Moisture Variability at 6-and 3-cm Sampling Depths: Implications for Microwave Sensor Validation [J].
Adams, Justin R. ;
Berg, Aaron A. ;
McNairn, Heather .
VADOSE ZONE JOURNAL, 2013, 12 (03)
[2]   Evaluation of SMOS Soil Moisture Products Over Continental US Using the SCAN/SNOTEL Network [J].
Al Bitar, Ahmad ;
Leroux, Delphine ;
Kerr, Yann H. ;
Merlin, Olivier ;
Richaume, Philippe ;
Sahoo, Alok ;
Wood, Eric F. .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2012, 50 (05) :1572-1586
[3]   An evaluation of ASCAT surface soil moisture products with in-situ observations in Southwestern France [J].
Albergel, C. ;
Ruediger, C. ;
Carrer, D. ;
Calvet, J. -C. ;
Fritz, N. ;
Naeimi, V. ;
Bartalis, Z. ;
Hasenauer, S. .
HYDROLOGY AND EARTH SYSTEM SCIENCES, 2009, 13 (02) :115-124
[4]  
Bell J.E., 2013, AM GEOPH UN FALL M
[5]   U.S. Climate Reference Network Soil Moisture and Temperature Observations [J].
Bell, Jesse E. ;
Palecki, Michael A. ;
Baker, C. Bruce ;
Collins, William G. ;
Lawrimore, Jay H. ;
Leeper, Ronald D. ;
Hall, Mark E. ;
Kochendorfer, John ;
Meyers, Tilden P. ;
Wilson, Tim ;
Diamond, Howard J. .
JOURNAL OF HYDROMETEOROLOGY, 2013, 14 (03) :977-988
[6]  
Boisvert J., 1995, Canadian journal of remote sensing, V21, P110
[7]   Large scale measurements of soil moisture for validation of remotely sensed data: Georgia soil moisture experiment of 2003 [J].
Bosch, DD ;
Lakshmi, V ;
Jackson, TJ ;
Choi, M ;
Jacobs, JM .
JOURNAL OF HYDROLOGY, 2006, 323 (1-4) :120-137
[8]   NEAR-SURFACE SOIL-MOISTURE ESTIMATION FROM MICROWAVE MEASUREMENTS [J].
BRUCKLER, L ;
WITONO, H ;
STENGEL, P .
REMOTE SENSING OF ENVIRONMENT, 1988, 26 (02) :101-121
[9]   DIELECTRIC-PROPERTIES AND INFLUENCE OF CONDUCTIVITY IN SOILS AT ONE TO 50 MEGAHERTZ [J].
CAMPBELL, JE .
SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1990, 54 (02) :332-341
[10]   Evaluation of soil moisture extremes for agricultural productivity in the Canadian prairies [J].
Champagne, C. ;
Berg, A. A. ;
McNairn, H. ;
Drewitt, G. ;
Huffman, T. .
AGRICULTURAL AND FOREST METEOROLOGY, 2012, 165 :1-11