Effect of the number of peak expiratory flow readings per day on the estimation of diurnal variation

被引:23
作者
Gannon, PFG
Newton, DT
Pantin, CFA
Burge, PS [1 ]
机构
[1] Birmingham Heartlands Hosp, Occupat Lung Dis Unit, Birmingham B9 5ST, W Midlands, England
[2] Keele Univ, Ind & Community Hlth Res Ctr, Postgrad Med Sch, N Staffordshire Hosp, Stoke On Trent ST4 7NY, Staffs, England
关键词
diurnal variation; peak expiratory flow; asthma;
D O I
10.1136/thx.53.9.790
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background-The number of peak expiratory flow (PEF) readings required per day to assess diurnal variation accurately is not known; published studies have used between two and seven PEF readings per day. This study compares the diurnal variation calculated using 2-10 PEF readings per day, Methods-All days with 10 readings were selected from a database of PEF records. For each day, diurnal variations calculated using 2-9 of the readings available were compared with that calculated using the full 10 PEF readings. Diurnal variation calculated using all 10 readings was taken as the true diurnal variation, When less than 10 readings were used the readings were evenly spaced over waking hours. Diurnal variation was calculated as maximum - minimum/predicted. Results-Two hundred and 25 days with 10 readings per day were selected from PEF records provided by 63 individuals. When only two PEF readings per day were used, the limits of agreement suggested a possible underestimate of true diurnal variation, calculated using all 10 readings, of 1.23-15.10%. The possible underestimate fell to 0.27-3.96% when calculated using four evenly spaced readings. Analysis of the timing of the highest PEF reading of the day was undertaken for rest and work days, This showed a mean (SD) timing of 13:56 (4:56 hours) for rest days and 11:47 (5:59 hours) for work days, Conclusions-Clinically significant underestimates of true diurnal variation may be seen when only small numbers of PEF readings per day are used in its calculation, At and above four readings the results suggest that the underestimate becomes increasingly insignificant in terms of the diagnosis and treatment of asthma, Analysis of the timing of the highest PEF reading of the day showed a wide variation, precluding the ability to capture the true diurnal variation with just two or three carefully timed PEF readings per day. The authors suggests that at least four readings per day should be performed, evenly spaced during waking hours, to obtain an accurate assessment of diurnal variation in PEF.
引用
收藏
页码:790 / 792
页数:3
相关论文
共 9 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] MEASUREMENTS OF MORNINGS AND EVENING AIR-FLOW GROSSLY UNDERESTIMATE THE CIRCADIAN VARIABILITY OF FEV(1) AND PEAK EXPIRATORY FLOW-RATE IN ASTHMA
    DALONZO, GE
    STEINIJANS, VW
    KELLER, A
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 152 (03) : 1097 - 1099
  • [3] COMPARISON OF NORMAL AND ASTHMATIC CIRCADIAN-RHYTHMS IN PEAK EXPIRATORY FLOW-RATE
    HETZEL, MR
    CLARK, TJH
    [J]. THORAX, 1980, 35 (10) : 732 - 738
  • [4] THE DISTRIBUTION OF PEAK EXPIRATORY FLOW VARIABILITY IN A POPULATION-SAMPLE
    HIGGINS, BG
    BRITTON, JR
    CHINN, S
    JONES, TD
    JENKINSON, D
    BURNEY, PGJ
    TATTERSFIELD, AE
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 140 (05): : 1368 - 1372
  • [5] LEE HS, 1991, BRIT J IND MED, V48, P275
  • [6] HOW MANY TIMES PER DAY SHOULD PEAK EXPIRATORY FLOW-RATES BE ASSESSED WHEN INVESTIGATING OCCUPATIONAL ASTHMA
    MALO, JL
    COTE, J
    CARTIER, A
    BOULET, LP
    LARCHEVEQUE, J
    CHANYEUNG, M
    [J]. THORAX, 1993, 48 (12) : 1211 - 1217
  • [7] THE NORMAL RANGE OF DIURNAL CHANGES IN PEAK EXPIRATORY FLOW-RATES - RELATIONSHIP TO SYMPTOMS AND RESPIRATORY-DISEASE
    QUACKENBOSS, JJ
    LEBOWITZ, MD
    KRZYZANOWSKI, M
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 143 (02): : 323 - 330
  • [8] FIELD SURVEY OF CIRCADIAN-RHYTHM IN PEF OF ELECTRONICS WORKERS SUFFERING FROM COLOPHONY-INDUCED ASTHMA
    RANDEM, B
    SMOLENSKY, MH
    HSI, B
    ALBRIGHT, D
    BURGE, S
    [J]. CHRONOBIOLOGY INTERNATIONAL, 1987, 4 (02) : 263 - 271
  • [9] REVSBECH P, 1989, BRIT J IND MED, V46, P566