HRP-based biosensor for monitoring rifampicin

被引:48
作者
Lomillo, MAA
Kauffmann, JM
Martinez, MJA
机构
[1] Univ Burgos, Dept Quim, Fac Ciencias, Area Quim Analit, E-09001 Burgos, Spain
[2] Free Univ Brussels, Inst Pharm, B-1050 Brussels, Belgium
关键词
electrodeposited polypyrrole; HRP biosensor; rifampicin; experimental design;
D O I
10.1016/S0956-5663(02)00251-8
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Pyrrole was electropolymerized onto a Pt electrode in the presence of LiClO4 and horseradish peroxidase (HRP). This HRP-based biosensor has been used for the amperometric detection of rifampicin (RIF) in the presence of a constant concentration of H2O2. The C-H2O2 as well as the applied potential (E-ap) and the pH of the phosphate buffer have simultaneously been optimized through a central composite design. Under these conditions, repeatability, reproducibility, and stability of the modified electrode have been analyzed. The detection limit for RIF has been calculated taking into account the probability of false-positive (alpha) and -negative (beta), reaching a value of 5.06 x 10(-6) mol dm(-3). The biosensor was applied to the determination of RIF in pharmaceutical preparations and biological samples. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1165 / 1171
页数:7
相关论文
共 29 条
[1]   TUBERCULOSIS IN THE 1990S [J].
BARNES, PF ;
BARROWS, SA .
ANNALS OF INTERNAL MEDICINE, 1993, 119 (05) :400-410
[2]  
Box G.E.P., 1989, ESTADISTICA INVESTIG
[3]   Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review [J].
Cosnier, S .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :443-456
[4]   Hydrogen peroxide sensitive biosensor based on plant peroxidases entrapped in Os-modified polypyrrole films [J].
Gaspar, S ;
Habermüller, K ;
Csöregi, E ;
Schuhmann, W .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (01) :63-68
[5]  
*GPES, 2000, GEN PURP EL SYST WIN
[6]  
*ISO 11843 2, 2000, CAP DET GEN SWITZ
[7]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF RIFAMPICIN IN HUMAN SERUM [J].
JAMALUDDIN, ABM ;
SARWAR, G ;
RAHIM, MA ;
RAHMAN, MK .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 525 (02) :495-497
[8]   HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHIC METHOD FOR MONITORING DEGRADATION PRODUCTS OF RIFAMPICIN IN DRUG EXCIPIENT INTERACTION STUDIES [J].
JINDAL, KC ;
CHAUDHARY, RS ;
GANGWAL, SS ;
SINGLA, AK ;
KHANNA, S .
JOURNAL OF CHROMATOGRAPHY A, 1994, 685 (01) :195-199
[9]   Determination of rifabutin in human plasma by high-performance liquid chromatography with ultraviolet detection [J].
Lau, YY ;
Hanson, GD ;
Carel, BJ .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 676 (01) :125-130
[10]  
Lomillo MAA, 2002, ELECTROANAL, V14, P634