Assessment of the acoustic properties of common tissue-mimicking test phantoms

被引:178
作者
Browne, JE
Ramnarine, KV
Watson, AJ
Hoskins, PR
机构
[1] Western Infirm & Associated Hosp, Ultrasound Equipment Evaluat Project, Dept Clin Phys, Glasgow, Lanark, Scotland
[2] Univ Hosp Leicester, Dept Med Phys, Leicester, Leics, England
[3] Univ Edinburgh, Dept Med Phys, Edinburgh, Midlothian, Scotland
关键词
tissue-mimicking; speed of sound; attenuation; backscatter; temperature-dependence; quality control;
D O I
10.1016/S0301-5629(03)00053-X
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound (US) test phantoms incorporating tissue-mimicking materials (TMMs) play an important role in the quality control (QC) and performance testing of US equipment. Three commercially available TMMs (Zerdine(TM) from CIRS Inc.; condensed-milk-based gel from Gammex RMI; urethane-rubber-based from ATS Labs) and a noncommercial agar-based TMM, were investigated. Acoustic properties were measured over the frequency range 2.25 to 15 MHz at a range of ambient temperatures (10 to 35degreesC). The acoustic velocity of the TMMs remained relatively constant with increasing frequency. Only the agar-based TMM had a linear increase of attenuation with frequency, with the other materials exhibiting nonlinear responses to varying degrees (f(1.08) to f(1.83)). The acoustic velocity and attenuation coefficient of all the TMMs varied with temperature, with the urethane-rubber TMM showing the greatest variation of +/-1.2% for acoustic velocity and +/-12% for attenuation coefficient. The data obtained in this study highlight the importance of greater knowledge of the acoustic behavior of TMMs to variations in both frequency and temperature, to ensure that accurate and precise measurements are obtained during QC and performance testing. (E-mail: jacinta.browne@northglasgow. scot.nhs.uk) (C) 2003 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:1053 / 1060
页数:8
相关论文
共 16 条
[1]  
AIUM, 1990, STANDARD METHODS MEA, P43
[2]  
BROWNE JE, 2002, J ULTRAS MED, V21, pS9
[3]   SPEED OF SOUND IN PURE WATER [J].
DELGROSS.VA ;
MADER, CW .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1972, 52 (05) :1442-&
[4]  
DUDLEY NJ, 2001, EUR J ULTRASOUND S, V13, pS23
[5]   The effect of acoustic velocity on phantom measurements [J].
Goldstein, L .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (07) :1133-1143
[6]  
IBALL GR, 2002, EUR J ULTRASOUND S, V15, pS36
[7]  
*IEC, 1996, IEC PUBL, V1390
[8]  
International Electrotechnical Commission [IEC], 2001, IEC PUBL
[9]   DETERMINATION OF THE NONLINEARITY PARAMETER B/A OF BIOLOGICAL MEDIA [J].
LAW, WK ;
FRIZZELL, LA ;
DUNN, F .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (02) :307-318
[10]   Liquid or solid ultrasonically tissue-mimicking materials with very low scatter [J].
Madsen, EL ;
Frank, GR ;
Dong, F .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (04) :535-542