Sources and impact of artifacts on clinical three-dimensional ultrasound imaging

被引:85
作者
Nelson, TR [1 ]
Pretorius, DH
Hull, A
Riccabona, M
Sklansky, MS
James, G
机构
[1] Univ Calif San Diego, Dept Radiol, Div Phys, La Jolla, CA 92014 USA
[2] Univ Calif San Diego, Dept Reprod Med, La Jolla, CA 92014 USA
[3] Univ Calif San Diego, Dept Pediat, La Jolla, CA 92014 USA
[4] Karl Franzens Univ Graz, Dept Radiol & Pediat, Graz, Austria
关键词
3D ultrasound; acoustic artifacts; ultrasound;
D O I
10.1046/j.1469-0705.2000.00180.x
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of this paper is to investigate, identify and discuss artifacts and their sources arising in three-dimensional ultrasound (3D US) in clinical practice in order to increase the awareness of clinicians and sonographers with respect to common 3D US artifacts and to use this increased awareness to avoid or reduce the occurrence of misdiagnosis in 3D US studies. Patient 3D US data were acquired using several different scanners and reviewed interactively on the scanner and graphics workstations. Artifacts were catalogued according to artifact origin. Two-dimensional ultrasound (2D US) artifacts were classified whether they were of a B-mode or color/power Doppler origin and their presentation in the original scan planes and the resulting volume re-sliced planes and rendered images was identified. Artifacts unique to 3D US were observed, noted and catalogued on the basis of whether they arose during acquisition, rendering or volume editing operations. Acoustic artifacts identified included drop-out, shadowing, etc. whose presentation depended on the relationship between slice and imaging plane orientation. Color/power Doppler artifacts were related to gain, aliasing, and flash which could add apparent structure or confusion to the volume images. Rendered images also demonstrated artifacts due to shadowing and motion of adjacent structures, cardiac motion or pulsatility of the cardiac septum or vessel walls. Editing artifacts potentially removed important structures. Three-dimensional ultrasound is prone to the same types of artifacts encountered in 2D US imaging plus others unique to volume acquisition and visualization. The consequences of these diagnostically significant artifacts include mimicking of abnormal development, masses, or missing structures thus requiring careful study before reaching a diagnosis.
引用
收藏
页码:374 / 383
页数:10
相关论文
共 16 条
[1]   Three-dimensional ultrasonography of the fetal distal lower extremity: Normal and abnormal [J].
Budorick, NE ;
Pretorius, DH ;
Johnson, DD ;
Nelson, TR ;
Tartar, MK ;
Lou, KV .
JOURNAL OF ULTRASOUND IN MEDICINE, 1998, 17 (10) :649-660
[2]   3D ULTRASONIC IMAGE FEATURE LOCALIZATION BASED ON MAGNETIC SCANHEAD TRACKING - IN-VITRO CALIBRATION AND VALIDATION [J].
DETMER, PR ;
BASHEIN, G ;
HODGES, T ;
BEACH, KW ;
FILER, EP ;
BURNS, DH ;
STRANDNESS, DE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (09) :923-936
[3]   Three-dimensional ultrasound of the fetal spine [J].
Johnson, DD ;
Pretorius, DH ;
Riccabona, M ;
Budorick, NE ;
Nelson, TR .
OBSTETRICS AND GYNECOLOGY, 1997, 89 (03) :434-438
[4]  
Kremkau F, 1989, DIAGNOSTIC ULTRASOUN
[5]  
KREMKAU FW, 1986, J ULTRAS MED, V5, P227
[6]  
KREMKAU FW, 1990, DOPPLER ULTRASOUND
[7]   The assessment of ovarian tumor angiogenesis: what does three-dimensional power Doppler add? [J].
Kurjak, A ;
Kupesic, S ;
Breyer, B ;
Sparac, V ;
Jukic, S .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1998, 12 (02) :136-146
[8]  
Levental M, 1998, J ULTRAS MED, V17, P341
[9]  
NELSON TR, 1995, RADIOLOGY, V197, P191
[10]  
NELSON TR, 1996, J ULTRAS MED, V158, P1