On-line measurement of particle size distribution and mass flow rate of particles in a pneumatic suspension using combined imaging and electrostatic sensors

被引:35
作者
Carter, RM
Yan, Y [1 ]
Cameron, SD
机构
[1] Univ Kent, Dept Elect, Canterbury CT2 7NT, Kent, England
[2] Mitsui Babcock Energy Ltd, Glasgow PA4 8DJ, Lanark, Scotland
关键词
particulate flow; pneumatic conveying; imaging; electrostatic; mass flow rate; on-line; size distribution;
D O I
10.1016/j.flowmeasinst.2005.03.005
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents a novel instrumentation system that uses a combination of electrostatic and digital imaging sensors. An inferential approach is adopted for the mass flow measurement of particles, velocity and volumetric concentration of particles being measured independently. The velocity of particles is determined by cross correlating two signals derived from a pair of electrostatic sensors and the volumetric concentration of particles is obtained using a novel digital imaging sensor, which also provides particle size distribution data. The basic principles and limits of operation of the imaging sensor are discussed and explained. Results obtained from a pneumatic conveyor are presented which demonstrate good performance of the measurement system for both mass flow metering (accurate to about +/- 6%) and particle sizing (reliable to around +/- 2.5%). Particle size distribution results are also included and the insensitivity of particle sizing to changes in velocity and concentration is assessed. In addition, on-line sizing results are compared to off-line results, measured using an accepted laser diffraction based instrument, and good agreement is observed. In general, the results obtained are encouraging and the system shows great promise. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:309 / 314
页数:6
相关论文
共 9 条
[1]   On-line particle sizing of pulverized and granular fuels using digital imaging techniques [J].
Carter, RM ;
Yan, Y .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (07) :1099-1109
[2]  
CARTER RM, 2003, P SENS THEIR APPL 2, V12
[3]   DROP SIZE MEASUREMENT IN A 2-PHASE SWIRLING FLOW USING IMAGE-PROCESSING TECHNIQUES [J].
KUMAR, R ;
KANNAN, S .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1994, 37 (04) :559-570
[4]   Design and evaluation of electrostatic sensors for the measurement of velocity of pneumatically conveyed solids [J].
Ma, J ;
Yan, Y .
FLOW MEASUREMENT AND INSTRUMENTATION, 2000, 11 (03) :195-204
[5]   Stereo imaging for simultaneous measurement of size and velocity of particles in dispersed two-phase flow [J].
Nishino, K ;
Kato, H ;
Torii, K .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2000, 11 (06) :633-645
[6]  
Pohl M, 2001, PBE INT MAY, P25
[7]   Mass flow measurement of bulk solids in pneumatic pipelines [J].
Yan, Y .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (12) :1687-1706
[8]  
YAN Y, 2001, GUIDE FLOW MEASUREME
[9]  
[No title captured]