Exact mass measurements for confirmation of pesticides and herbicides determined by liquid chromatography/time-of-flight mass spectrometry

被引:40
作者
Maizels, M
Budde, WL
机构
[1] US EPA, Off Res & Dev, Natl Exposure Res Lab, Cincinnati, OH 45268 USA
[2] Oak Ridge Inst Sci & Educ, Cincinnati, OH 45268 USA
关键词
D O I
10.1021/ac010601o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The accuracy and precision of exact mass measurements are determined using positive ions formed in the electrospray of 10 nonvolatile or thermally unstable carbamate, urea, and thiourea pesticides and herbicides. Environmentally significant similar to 7-ng quantities of the analytes were separated with microbore liquid chromatography, and the exact mass measurements were made in real time with a benchtop time-of-flight mass spectrometer. The positive ion electrospray mass spectra of the analytes generally consist of one or a few ions which are usually adducts of the molecule with a proton, a sodium ion, or an ammonium ion. Fragment ions and the rich mass spectra typical of electron ionization (EI) are generally not produced in the soft electrospray ionization process. Confirmation of the identity of a nonvolatile pesticide or herbicide depends largely on the masses of the few ions formed and the retention time, which can vary with chromatography conditions. Identifications of these analytes in environmental or other samples are less certain than identifications of volatile pesticides determinated by gas chromatography and El mass spectrometry. The benchtop time-of-flight mass spectrometer was equipped with an electrostatic mirror, and resolving powers of 3500-5000 were routinely obtained and used for these exact mass measurements. This type of mass spectrometer is significantly less costly and complex than other types of mass spectrometers with exact mass measurement capabilities. The mean errors from three replicate exact mass measurements of the 10 test analytes were in the range of 0-5.4 parts-per-million. Potential interferences from substances with similar exact masses were evaluated.
引用
收藏
页码:5436 / 5440
页数:5
相关论文
共 10 条
[1]   ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY [J].
BRUINS, AP ;
COVEY, TR ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1987, 59 (22) :2642-2646
[2]  
BUDDE WL, 2001, ANAL MASS SPECTROMET, pCH5
[3]   The new time-of-flight mass spectrometry [J].
Cotter, RJ .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :445A-451A
[4]   Negative ion electrospray of bromo- and chloroacetic acids and an evaluation of exact mass measurements with a bench-top time-of-flight mass spectrometer [J].
Debré, O ;
Budde, WL ;
Song, XB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (09) :809-821
[5]  
*NIST, 1998, NIST EPA NIH MASS SP
[6]  
Russell DH, 1997, J MASS SPECTROM, V32, P263, DOI 10.1002/(SICI)1096-9888(199703)32:3<263::AID-JMS501>3.3.CO
[7]  
2-T
[8]   High-throughput proteomics using high efficiency multiple-capillary liquid chromatography with on-line high-performance ESI FTICR mass spectrometry [J].
Shen, YF ;
Tolic, N ;
Zhao, R ;
Pasa-Tolic, L ;
Li, LJ ;
Berger, SJ ;
Harkewicz, R ;
Anderson, GA ;
Belov, ME ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :3011-3021
[9]   Determination of carbamate, urea, and thiourea pesticides and herbicides in water [J].
Wang, N ;
Budde, WL .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :997-1006
[10]   Accurate mass liquid chromatography/mass spectrometry on quadrupole orthogonal acceleration time-of flight mass analyzers using switching between separate sample and reference sprays. 2. Applications using the dual-electrospray ion source [J].
Wolff, JC ;
Eckers, C ;
Sage, AB ;
Giles, K ;
Bateman, R .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2605-2612