A novel one-step, highly sensitive fluorometric assay to evaluate cell-mediated cytotoxicity

被引:298
作者
Nociari, MM
Shalev, A
Benias, P
Russo, C
机构
[1] Cornell Univ, Coll Med, Lab Immunol & Gerontol,Immunol Program, Div Geriatr,Grad Sch Med Sci, New York, NY 10021 USA
[2] Cornell Univ, Coll Med, Lab Immunol & Gerontol,Immunol Program, Div Int Med & Infect Dis,Grad Sch Med Sci, New York, NY 10021 USA
关键词
cell-mediated cytotoxicity; natural killer activity; NK; CTL; AlamarBlue; fluorescence;
D O I
10.1016/S0022-1759(98)00028-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, a fluorometric method using alamarBlue has been developed for detecting cell-mediated cytotoxicity in vitro. AlamarBlue is a non-toxic metabolic indicator of viable cells that becomes fluorescent upon mitochondrial reduction. Specific lysis of targets by effector cells is quantified by comparing the total number of viable cells in wells containing effector and targets together, with wells where target and effector cells were separately seeded. Cell-mediated cytotoxic activity by alloreactive T cells and natural killer cells has been detected using a novel application of the alamarBlue technique. The assay that we have developed to detect cell-mediated cytotoxicity is extremely sensitive and specific and requires a significant lower number of effector cells than the standard Cr-51 assay. Since alamarBlue reagent is non-toxic to cells and the assay can be performed under sterile conditions, effector cells may be recovered at the end for further analysis or cell expansion, if desired. Direct comparison of cell-mediated cytotoxicity measured by the alamarBlue method with the standard Cr-51 release assay revealed that the former method is as specific and more sensitive than the conventional assay. Moreover, very small inter and intra-assay variations have been observed for alamarBlue cytotoxicity assays, In conclusion, this study shows that the alamarBlue assay is an extremely sensitive, economical, simple and non-toxic procedure to evaluate cell-mediated cytotoxicity that yields accurate results using a limited number of effector cells. Furthermore, since this assay is a one-step procedure, and does not involve any risk for the personnel, it may be useful to analyze automatically cell-mediated cytotoxicity in a large number of samples. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:157 / 167
页数:11
相关论文
共 29 条
[1]   A NEW RAPID AND SIMPLE NONRADIOACTIVE ASSAY TO MONITOR AND DETERMINE THE PROLIFERATION OF LYMPHOCYTES - AN ALTERNATIVE TO [H-3] THYMIDINE INCORPORATION ASSAY [J].
AHMED, SA ;
GOGAL, RM ;
WALSH, JE .
JOURNAL OF IMMUNOLOGICAL METHODS, 1994, 170 (02) :211-224
[2]  
[Anonymous], 1991, CURRENT PROTOCOLS IM
[3]   TH1 CD4+ LYMPHOCYTES DELETE ACTIVATED MACROPHAGES THROUGH THE FAS/APO-1 ANTIGEN PATHWAY [J].
ASHANY, D ;
SONG, X ;
LACY, E ;
NIKOLICZUGIC, J ;
FRIEDMAN, SM ;
ELKON, KB .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (24) :11225-11229
[4]   EVALUATION OF ALAMAR COLORIMETRIC MIC METHOD FOR ANTIMICROBIAL SUSCEPTIBILITY TESTING OF GRAM-NEGATIVE BACTERIA [J].
BAKER, CN ;
BANERJEE, SN ;
TENOVER, FC .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (05) :1261-1267
[5]   FLUORESCENT EUROPIUM CHELATES AS TARGET-CELL MARKERS IN THE ASSESSMENT OF NATURAL-KILLER-CELL CYTOTOXICITY [J].
BLOMBERG, K ;
ULFSTEDT, AC .
JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 160 (01) :27-34
[6]   AUTOMATED FLUOROMETRIC ASSAY FOR T-CELL CYTO-TOXICITY [J].
BRENAN, M ;
PARISH, CR .
JOURNAL OF IMMUNOLOGICAL METHODS, 1988, 112 (01) :121-131
[7]   CARBOXYFLUORESCEIN FLUOROCHROMASIA ASSAYS .1. NON-RADIOACTIVELY LABELED CELL-MEDIATED LYMPHOLYSIS [J].
BRUNING, JW ;
KARDOL, MJ ;
ARENTZEN, R .
JOURNAL OF IMMUNOLOGICAL METHODS, 1980, 33 (01) :33-44
[8]  
BRUNNER KT, 1968, IMMUNOLOGY, V14, P181
[9]   QUANTIFICATION OF MITOGEN-INDUCED HUMAN LYMPHOCYTE-PROLIFERATION - COMPARISON OF ALAMARBLUE(TM) ASSAY TO H-3 THYMIDINE INCORPORATION ASSAY [J].
DEFRIES, R ;
MITSUHASHI, M .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1995, 9 (02) :89-95
[10]   A FLUOROMETRIC ASSAY FOR DETERMINING CELL-GROWTH IN LYMPHOCYTE-PROLIFERATION AND LYMPHOKINE ASSAYS [J].
DOTSIKA, EN ;
SANDERSON, CJ .
JOURNAL OF IMMUNOLOGICAL METHODS, 1987, 105 (01) :55-62