Reproducibility and validity of a new test protocol for measuring isokinetic trunk extension strength

被引:43
作者
Dvir, Z [1 ]
Keating, J
机构
[1] Tel Aviv Univ, Sackler Fac Med, Dept Phys Therapy, IL-69978 Ramat Aviv, Israel
[2] La Trobe Univ, Sch Physiotherapy, Fac Hlth Sci, Bundoora, Vic 3083, Australia
关键词
trunk; muscle; strength; isokinetics; reproducibility; validity;
D O I
10.1016/S0268-0033(01)00038-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To investigate the reproducibility and validity of isokinetic trunk extension strength scores obtained using a range of motion of 20 degrees and velocities of 10 and 40 degrees /s. Background. Common protocols for testing trunk extension strength incorporate a range of motion of 40 degrees or more and test velocities of between 30 and 180 degrees /s. These test parameters may be neither necessary for portraying the strength profile of the muscles involved nor suitable for patients impaired with low back dysfunction. Design. Test-retest of maximal concentric and eccentric isokinetic trunk extension strength in healthy subjects. Methods. 17 women and 18 men were tested twice within 1-2 weeks. Tests were performed with subjects positioned in sitting. Results. The trunk extension strength scores revealed excellent agreement with the expected physiological moment-velocity curve. On average women's trunk extension strength was 62% that of men (range: 59.3-64.4%). The test-retest correlation coefficients were generally higher in women (0.70-0.87) than in men (0.52-0.78) and significant at P = 0.01. The standard error of measurement ranged between 13 and 21 N m for women and between 35 and 50 N in for men, which were equivalent to 9% and 15% of the mean strength in women and men, respectively. Conclusion. This study indicates that the present protocol may be validly applied in assessing trunk extension strength in normal women.
引用
收藏
页码:627 / 630
页数:4
相关论文
共 12 条
[2]   Identifying feigned isokinetic trunk extension effort in normal subjects - An efficiency study of the DEC [J].
Dvir, Z ;
Keating, J .
SPINE, 2001, 26 (09) :1046-1051
[3]  
Dvir Z, 1995, ISOKINETICS MUSCLE T
[4]   QUANTIFICATION OF LUMBAR FUNCTION .2. SAGITTAL PLANE TRUNK STRENGTH IN CHRONIC LOW-BACK-PAIN PATIENTS [J].
MAYER, TG ;
SMITH, SS ;
KEELEY, J ;
MOONEY, V .
SPINE, 1985, 10 (08) :765-772
[5]   QUANTIFICATION OF LUMBAR FUNCTION .3. PRELIMINARY DATA ON ISOKINETIC TORSO ROTATION TESTING WITH MYOELECTRIC SPECTRAL-ANALYSIS IN NORMAL AND LOW-BACK-PAIN SUBJECTS [J].
MAYER, TG ;
SMITH, SS ;
KONDRASKE, G ;
GATCHEL, RJ ;
CARMICHAEL, TW ;
MOONEY, V .
SPINE, 1985, 10 (10) :912-920
[6]  
MCGILL SM, 2000, CLIN BIOMECH, P103
[7]  
MCINTYRE DR, 1991, J SPINAL DISORD, V4, P90
[8]   TRUNK STRENGTH TESTING WITH ISO-MACHINES .2. EXPERIMENTAL EVALUATION OF THE CYBEX-II BACK TESTING SYSTEM IN NORMAL SUBJECTS AND PATIENTS WITH CHRONIC LOW-BACK-PAIN [J].
NEWTON, M ;
THOW, M ;
SOMERVILLE, D ;
HENDERSON, I ;
WADDELL, G .
SPINE, 1993, 18 (07) :812-824
[9]   ASSESSMENT OF ABDOMINAL AND BACK EXTENSOR FUNCTION - A QUANTITATIVE APPROACH AND RESULTS FOR CHRONIC LOW-BACK PATIENTS [J].
SMIDT, G ;
HERRING, T ;
AMUNDSEN, L ;
ROGERS, M ;
RUSSELL, A ;
LEHMANN, T .
SPINE, 1983, 8 (02) :211-219
[10]  
Smidt G L, 1980, J Orthop Sports Phys Ther, V1, P165