Comparative study of central corneal thickness measurement with slit-lamp optical coherence tomography and visante optical coherence tomography

被引:110
作者
Li, Haitao [1 ]
Leung, Christopher Kai Shun [1 ,2 ]
Wong, Lee [1 ]
Cheung, Carol Yim Lui [1 ]
Pang, Chi Pui [1 ]
Weinreb, Robert Neal [2 ]
Lam, Dennis Shun Chiu [1 ]
机构
[1] Chinese Univ Hong Kong, Hong Kong Eye Hosp, Dept Ophthalmol & Visual Sci, Kowloon, Hong Kong, Peoples R China
[2] Univ Calif San Diego, Hamilton Glaucoma Ctr, San Diego, CA 92103 USA
关键词
D O I
10.1016/j.ophtha.2007.07.006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the repeatability and reproducibility of central corneal thickness (CCT) measurements obtained by 2 anterior segment optical coherence tomography (OCT) imaging systems and to examine their agreements with ultrasound pachymetry. Design: Observational cross-sectional study. Participants: Fifty eyes from 50 healthy normal subjects were recruited. Methods: In one randomly selected eye in each subject, CCT was measured by slit-lamp OCT (SLOCT), Visante OCT, and ultrasound pachymetry. For anterior segment OCT measurements, both automatic and manual CCTs were obtained. Twenty-five of the 50 subjects were invited for 2 more visits within a week to evaluate repeatability and reproducibility of CCT measurement. Main Outcome Measures: Central corneal thickness measurement obtained by the 3 methods and their agreements. Intrasession and intersession within-subject standard deviation (S-w), precision (1.96xS(w)), coefficient of variation (CVw) (100xS(w)/overall mean), and intraclass correlation coefficient (ICC) were calculated to evaluate repeatability and reproducibility. Results: Good repeatability and reproducibility were found for both automatic and manual CCT measurements obtained by SLOCT and Visante OCT. For intrasession repeatability, CVw and ICC values ranged between 0.9% and 1.2% and 0.96 and 0.98, respectively. For intersession reproducibility, the respective CVw and ICC values ranged between 1.2% and 1.4% and 0.94 and 0.96. Although no significant difference was found between automatic/manual SLOCT measurements and ultrasound pachymetry, automatic Visante OCT CCT (535.7 +/- 30.2 mu m) was significantly less than CCT with ultrasound pachymetry (550.3 +/- 31.14 mu m) (P<0.001). In contrast, manual Visante OCT measurement (558.8 +/- 32.8 mu m) was slightly higher than ultrasound pachymetry (P<0.001). Nevertheless, SLOCT and Visante OCT measurement of CCT had 95% limits of agreement comparable to that of ultrasound pachymetry. The best agreement was observed in the manual SLOCT measurement (95% limits of agreement between -15.5 and 11.7 mu m). Conclusions: Both SLOCT and Visante OCT automatic and manual CCT measurements were reliable and showed comparable agreement with ultrasound pachymetry. Although the 2 anterior segment OCT imaging systems have similar design and working principles, clinicians should be aware of the differences in CCT measurement between the 2 anterior segment OCTs.
引用
收藏
页码:796 / 801
页数:6
相关论文
共 16 条
[1]   Evaluating central corneal thickness measurements with noncontact optical low-coherence reflectometry and contact ultrasound pachymetry [J].
Airiani, Suzanna ;
Trokel, Stephen L. ;
Lee, Shing M. ;
Braunstein, Richard E. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (01) :164-165
[2]   Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry [J].
Barkana, Y ;
Gerber, Y ;
Elbaz, U ;
Schwartz, S ;
Ken-Dror, G ;
Avni, I ;
Zadok, D .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) :1729-1735
[3]   Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry [J].
Bechmann, M ;
Thiel, MJ ;
Neubauer, AS ;
Ullrich, S ;
Ludwig, K ;
Kenyon, KR ;
Ulbig, MW .
CORNEA, 2001, 20 (01) :50-54
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach [J].
Doughty, MJ ;
Zaman, ML .
SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) :367-408
[6]   Comparison of Pentacam Scheimpflug camera with ultrasound pachymetry and 0 noncontact specular Microscopy in measuring central corneal thickness [J].
Fujioka, Miyuki ;
Nakamura, Makoto ;
Tatsumi, Yasuko ;
Kusuhara, Azusa ;
Maeda, Hidetaka ;
Negi, Akira .
CURRENT EYE RESEARCH, 2007, 32 (02) :89-94
[7]  
Gordon MO, 2002, ARCH OPHTHALMOL-CHIC, V120, P714
[8]   Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound [J].
Lackner, B ;
Schmidinger, G ;
Pieh, S ;
Funovics, MA ;
Skorpik, C .
OPTOMETRY AND VISION SCIENCE, 2005, 82 (10) :892-899
[9]   Comparison between central corneal thickness measurements by ultrasound pachymetry and optical coherence tomography [J].
Leung, Dexter Y. L. ;
Lam, Douglas K. T. ;
Yeung, Barry Y. M. ;
Lam, Dennis S. C. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (08) :751-754
[10]   Corneal pachymetry mapping with high-speed optical coherence tomography [J].
Li, Y ;
Shekhar, R ;
Huang, D .
OPHTHALMOLOGY, 2006, 113 (05) :792-799