Novel delivery method to reduce endothelial injury in Descemet Stripping Automated Endothelial Keratoplasty

被引:39
作者
Kuo, Anthony N. [1 ,2 ]
Harvey, Thomas M. [3 ]
Afshari, Natalie A. [1 ,2 ]
机构
[1] Duke Univ, Med Ctr, Ctr Eye, Durham, NC 27710 USA
[2] Duke Univ, Albert Eye Res Inst, Durham, NC USA
[3] Chippewa Valley Eye Clin, Eau Claire, WI USA
关键词
D O I
10.1016/j.ajo.2007.08.036
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To present a novel technique to deliver the endothelial graft in small incision Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) and to compare graft trauma between forceps delivery and the novel technique. DESIGN: Laboratory investigation with an interventional case report. METHODS: Ten pairs of human donor corneas were sectioned using an automated microkeratome system (Moria ALTK System, Antony, France). The recipient model was prepared by creating a 3 mm clear corneal wound in another human donor cornea. For each pair of corneas, one endothelial graft underwent single,fold delivery with forceps, while the other was delivered with the novel cartridge based technique. Each graft was stained with 0.25% trypan blue and 0.2% alizarin red, and digital photomicrographs were taken. A proportion of graft injury was calculated and differences were analyzed. Subsequently, a patient requiring DSAEK underwent the modified novel insertion technique. RESULTS: After insertion, the mean proportion of graft endothelial injury from forceps delivery through the ex vivo model was 26.02% (n = 10, standard deviation [SD] +/- 14.85%). The mean proportion of graft endothelial injury from cartridge delivery was 9.85 % (n = 10, SD +/- 4.33%). The median difference between the two methods was - 13 %, representing less endothelial injury with the cartridge. This difference was statistically significant (P =.006). The patient who underwent DSAEK with this technique had improved visual acuity and a clear graft at five months. CONCLUSIONS: In our surgical model, inserting an endothelial graft through a small corneal wound using a novel cartridge based technique created significantly less endothelial damage than with forceps insertion. Clinically, this technique was performed without complication.
引用
收藏
页码:91 / 96
页数:6
相关论文
共 13 条
[1]   Descemet-stripping automated endothelial keratoplasty [J].
Gorovoy, Mark S. .
CORNEA, 2006, 25 (08) :886-889
[2]  
Harvey TM, 2006, J REFRACT SURG, V22, P429
[3]   Corneal endothelial damage by air bubbles during phacoemulsification [J].
Kim, EK ;
Cristol, SM ;
Geroski, DH ;
McCarey, BE ;
Edelhauser, HF .
ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (01) :81-88
[4]   Early results of small-incision Descemet's stripping and automated endothelial keratoplasty [J].
Koenig, Steven B. ;
Covert, Douglas J. .
OPHTHALMOLOGY, 2007, 114 (02) :221-226
[5]   Phacoemulsification and modern cataract surgery [J].
Linebarger, EJ ;
Hardten, DR ;
Shah, GK ;
Lindstrom, RL .
SURVEY OF OPHTHALMOLOGY, 1999, 44 (02) :123-147
[6]   A technique to exercise the descemet membrane from a recipient cornea (descemetorhexis) [J].
Melles, GRJ ;
Wijdh, RHJ ;
Nieuwendaal, CP .
CORNEA, 2004, 23 (03) :286-288
[7]   Sutureless, posterior lamellar keratoplasty - A case report of a modified technique [J].
Melles, GRJ ;
Lander, F ;
Nieuwendaal, C .
CORNEA, 2002, 21 (03) :325-327
[8]   Descemet's stripping with endothelial keratoplasty in 200 eyes - Early challenges and techniques to enhance donor adherence [J].
Price, FW ;
Price, MO .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (03) :411-418
[9]  
Price FW, 2005, J REFRACT SURG, V21, P339
[10]   Descemet's stripping with endothelial keratoplasty - Comparative outcomes with microkeratome-dissected and manually dissected donor tissue [J].
Price, Marianne O. ;
Price, Francis W., Jr. .
OPHTHALMOLOGY, 2006, 113 (11) :1936-1942