High-grade loss of leukocytes and hematopoietic progenitor cells caused by erythrocyte-lysing procedures for flow cytometric analyses

被引:35
作者
Greve, B
Beller, C
Cassens, U
Sibrowski, W
Severin, E
Göhde, W
机构
[1] Univ Hosp Munster, Dept Radiobiol, D-48149 Munster, Germany
[2] Univ Hosp Munster, Dept Transfus Med, D-48149 Munster, Germany
来源
JOURNAL OF HEMATOTHERAPY & STEM CELL RESEARCH | 2003年 / 12卷 / 03期
关键词
D O I
10.1089/152581603322023052
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
All current-flow cytometric techniques use erythrocyte-lysing procedures before leukocyte analysis. We investigated the impact of four lysing procedures with different flow cytometric techniques on the loss of leukocytes and hematopoietic progenitor cells in blood samples. A total of 280 determinations out of 10 samples were measured by two flow cytometers (FCMs), using a FRCS-Calibur (Becton Dickinson) and a particle-analyzing system (PAS) with a "true volumetric unit" (Partec). All samples were prepared with four different commercially available erythrocyte-lysing reagents (n = 10, respectively). CD34(+) cells were determined in relation to counted leukocytes with both FCMs (dual platform determinations, 2-PF). In addition, further immunologic and nuclear staining determinations of cells with and without erythrocyte-lysing procedures were performed in the "true volumetric unit" (single platform mode 1-PF) using the PAS system (n = 10, respectively). In the 2-PF mode, both systems showed identical results for CD34+ cells (r = 0.997). The comparison of 1-PF and 2-PF modes with immunologic stainings revealed a mean decrease of 34.5% for absolute amounts of CD45(+) cells [in detail: Becton-Dickinson (BD) lysis 40%; Ortho Diagnostics (OD) lysis 31%; Uti lyse (UL) 38%; Cylyse (CL) 29%] and of 41.3% for absolute concentration of CD34(+) cells [in detail: BD lysis 45%; OD lysis 40%; UL lysis 45%; CL lysis 34 %] by the lysing procedures. In contrast, the nuclear stainings revealed a mean leukocyte loss of only 5 % for the nonlysed samples and of 12% for lysed samples. All investigated lysing procedures induced a large loss of leukocytes and progenitor cells, obviously due to cell membrane destruction as demonstrated for identical samples in the 1-PF and 2-PF modes by immunologic and nuclear staining methods.
引用
收藏
页码:321 / 330
页数:10
相关论文
共 33 条
[1]   Direct extracellular interaction between carbonic anhydrase IV and the human heart NBC1Na+/HCO3- cotransporter. [J].
Alvarez, BV ;
Loiselle, FB ;
Casey, JR .
JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 2002, 34 (09) :A19-A19
[2]   Technical aspects and clinical impact of hematopoietic progenitor subset quantification [J].
Baech, J ;
Johnsen, HE .
STEM CELLS, 2000, 18 (02) :76-86
[3]  
Basso G, 1998, BONE MARROW TRANSPL, V22, pS17
[4]  
BENDER JG, 1994, HEMATOPOIETIC STEM CELLS, P31
[5]  
Bossuyt X, 1997, CYTOMETRY, V30, P124
[6]  
Brando B, 2001, CYTOMETRY, V43, P154, DOI 10.1002/1097-0320(20010201)43:2<154::AID-CYTO1031>3.3.CO
[7]  
2-U
[8]   Comparison of volumetric capillary cytometry with standard flow cytometry for routine enumeration of CD34+cells [J].
Cabezudo, E ;
Querol, S ;
Cancelas, JA ;
García, J .
TRANSFUSION, 1999, 39 (08) :864-872
[9]   A novel true volumetric method for the determination of residual leucocytes in blood components [J].
Cassens, U ;
Greve, B ;
Tapernon, K ;
Nave, B ;
Severin, E ;
Sibrowski, W ;
Göhde, W .
VOX SANGUINIS, 2002, 82 (04) :198-206
[10]  
Cassens U, 1998, TRANSFUSION MED, V8, P111