Objective radiologic analysis of ground-glass opacity aimed at curative limited resection for small peripheral non-small cell lung cancer

被引:85
作者
Nakata, M
Sawada, S
Yamashita, M
Saeki, H
Kurita, A
Takashima, S
Tanemoto, K
机构
[1] Kawasaki Med Sch, Dept Surg, Div Thorac & Cardiovasc Surg, Kurashiki, Okayama 7010192, Japan
[2] Natl Shikoku Canc Ctr, Dept Surg, Matsuyama, Ehime, Japan
关键词
D O I
10.1016/j.jtcvs.2004.10.032
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The aim of this study was to evaluate the efficacy of the objective radiologic analysis of high-resolution computed tomographic images of small peripheral non-small cell lung cancer and to select the candidates for curative limited resection. Methods: High-resolution computed tomographic images of 146 surgically resected T1 N0 M0 peripheral non-small cell lung cancers were analyzed by using National Institutes of Health image software and classified on the basis of the percentage of ground-glass opacity within the tumor. Results: Eighty-seven percent of tumors with ground-glass opacity ratios of 90% to 100% (type I) were diagnosed as noninvasive bronchioloalveolar carcinoma, whereas 55.6% of tumors with ground-glass opacity ratios of 50% to 89% (type II) consisted of adenocarcinoma. Tumors with ground-glass opacity ratios of 50% or more (type I/II) had no nodal involvement, whereas nodal metastases were identified in 20.0% of tumors with ground-Glass opacity ratios of 10% to 49% (type III) and 24.4% of tumors with ground-glass opacity ratios of less than 10% (type IV). No tumors with ground-glass opacity ratios of 50% or more showed vessel infiltration, except for one lesion with a ground-glass opacity ratio of 50%. The 3-year disease-free survival was 97.7% for type I/II, 86.1% for type III, and 78.5% for type IV tumors. Conclusions: The objective quantitative radiologic analysis with National Institutes of Health image software exhibited a good correlation with the histologic classification, pathologic invasiveness, and postoperative outcome of small peripheral lung cancer. Patients with tumors that have ground-glass opacity ratios of greater than 50% are considered to be possible candidates for limited pulmonary resection.
引用
收藏
页码:1226 / 1231
页数:6
相关论文
共 25 条
[1]   Evolution of peripheral lung adenocarcinomas: CT findings correlated with histology and tumor doubling time [J].
Aoki, T ;
Nakata, H ;
Watanabe, H ;
Nakamura, K ;
Kasai, T ;
Hashimoto, H ;
Yasumoto, K ;
Kido, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (03) :763-768
[2]   Lymph node involvement, recurrence, and prognosis in resected small, peripheral, non-small-cell lung carcinomas: Are these carcinomas candidates for video-assisted lobectomy? [J].
Asamura, H ;
Nakayama, H ;
Kondo, H ;
Tsuchiya, R ;
Shimosato, Y ;
Naruke, T .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (06) :1125-1134
[3]   Glossary of terms for CT of the lungs: Recommendations of the Nomenclature Committee of the Fleischner Society [J].
Austin, JHM ;
Muller, NL ;
Friedman, PJ ;
Hansell, DM ;
Naidich, DP ;
RemyJardin, M ;
Webb, WR ;
Zerhouni, EA .
RADIOLOGY, 1996, 200 (02) :327-331
[4]   Prognostic value of bronchiolo-alveolar carcinoma component of small lung adenocarcinoma [J].
Higashiyama, M ;
Kodama, K ;
Yokouchi, H ;
Takami, K ;
Mano, M ;
Kido, S ;
Kuriyama, K .
ANNALS OF THORACIC SURGERY, 1999, 68 (06) :2069-2073
[5]   RANDOMIZED TRIAL OF LOBECTOMY VERSUS LIMITED RESECTION FOR T1 N0 NON-SMALL-CELL LUNG-CANCER [J].
HOLMES, CE ;
RUCKDESCHEL, JC ;
JOHNSTON, M ;
THOMAS, PA ;
DESLAURIERS, J ;
GROVER, FL ;
HILL, LD ;
FELD, R ;
GINSBERG, RJ ;
MOUNTAIN, CF ;
DZUIBAN, S ;
KIELY, M ;
MCKNEALLY, MF ;
MOORES, DWO ;
RAMNES, C ;
WAGNER, H ;
BUNN, P ;
CHU, H ;
DIENHART, D ;
HAZUKA, M ;
KINZIE, J ;
SORENSEN, J ;
VANCE, V ;
BRAUN, T ;
HOPEMAN, A ;
KANE, M ;
RUSS, P ;
WHITMAN, GJR ;
FALL, SM ;
HANSEN, DP ;
HENDERSON, RH ;
MONCRIEF, CL ;
PAULING, F ;
SIMS, J ;
TELL, D ;
WISELYCARR, S ;
ABERNATHY, CM ;
CLARK, DA ;
MCCROSKEY, B ;
MOORE, G ;
MOORE, F ;
MYERS, A ;
WHITE, M ;
BROOKS, RJ ;
BULL, M ;
JOHNSON, FB ;
NEIMYR, M ;
PAQUETTE, FR ;
SACCOMANNO, G ;
LAD, T .
ANNALS OF THORACIC SURGERY, 1995, 60 (03) :615-622
[6]   Peripheral lung cancer: Screening and detection with low-dose spiral CT versus radiography [J].
Kaneko, M ;
Eguchi, K ;
Ohmatsu, H ;
Kakinuma, R ;
Naruke, T ;
Suemasu, K ;
Moriyama, N .
RADIOLOGY, 1996, 201 (03) :798-802
[7]   Quantification of ground-glass opacity on high-resolution CT of small peripheral adenocarcinoma of the lung: Pathologic and prognostic implications [J].
Kim, EA ;
Johkoh, T ;
Lee, KS ;
Han, J ;
Fujimoto, K ;
Sadohara, J ;
Yang, PS ;
Kozuka, T ;
Honda, O ;
Kim, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (06) :1417-1422
[8]   Prognostic value of ground-glass opacity found in small lung adenocarcinoma on high-resolution CT scanning [J].
Kodama, K ;
Higashiyama, M ;
Yokouchi, H ;
Takami, K ;
Kuriyama, K ;
Mano, M ;
Nakayama, T .
LUNG CANCER, 2001, 33 (01) :17-25
[9]   Ground-glass opacity on thin-section CT: Value in differentiating subtypes of adenocarcinoma of the lung [J].
Kuriyama, K ;
Seto, M ;
Kasugai, T ;
Higashiyama, M ;
Kido, S ;
Sawai, Y ;
Kodama, K ;
Kuroda, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (02) :465-469
[10]   Objective definition and measurement method of ground-glass opacity for planning limited resection in patients with clinical stage IA adenocarcinoma of the lung [J].
Matsuguma, H ;
Nakahara, R ;
Anraku, M ;
Kondo, T ;
Tsuura, Y ;
Kamiyama, Y ;
Mori, K ;
Yokoi, K .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (06) :1102-1105