The CDF Cherenkov luminosity monitor

被引:46
作者
Acosta, D
Klimenko, S
Konigsberg, J [1 ]
Korytov, A
Mitselmakher, G
Nguyele, A
Nomerotski, A
Safonov, A
Stanek, R
Tsybychev, D
Vidal, R
Wang, SM
Wong, M
机构
[1] Univ Florida, Gainesville, FL 32611 USA
[2] Fermi Natl Lab, Batavia, IL USA
关键词
Cherenkov; luminosity; detectors;
D O I
10.1016/S0168-9002(00)01294-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have built a novel device for precision measurements of luminosity in the CDF experiment at the high p(p) over bar collision rates expected during Run II. The detector consists of long, conical, gaseous Cherenkov counters that point to the collision region and monitor the average number of inelastic p(p) over bar interactions by measuring the number of particles, and their arrival time, in each bunch crossing. For these primary particles, using isobutane at atmospheric pressure as a radiator, a large amount of Cherenkov light (similar to 100 photoelectrons) will be collected, with good amplitude and time resolutions, onto small and efficient PMTs. Suitable amplitude thresholds will be applied to discriminate from non-primary particles and other backgrounds which yield little light in the counters. This detector is expected to reliably perform bunch-by-bunch luminosity measurements at peak instantaneous luminosities of 2 x 10(32) cm(-2) s(-1) with six interactions per bunch crossing, on average, and respond to a 132 ns bunch spacing. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:540 / 544
页数:5
相关论文
共 6 条
[1]   MEASUREMENT OF THE ANTIPROTON-PROTON TOTAL CROSS-SECTION AT ROOT-S=546 AND 1800 GEV [J].
ABE, F ;
ALBROW, M ;
AMIDEI, D ;
ANWAYWIESE, C ;
APOLLINARI, G ;
ATAC, M ;
AUCHINCLOSS, P ;
AZZI, P ;
BACCHETTA, N ;
BADEN, AR ;
BADGETT, W ;
BAILEY, MW ;
BAMBERGER, A ;
DEBARBARO, P ;
BARBAROGALTIERI, A ;
BARNES, VE ;
BARNETT, BA ;
BAUER, G ;
BAUMANN, T ;
BEDESCHI, F ;
BEHRENDS, S ;
BELFORTE, S ;
BELLETTINI, G ;
BELLINGER, J ;
BENJAMIN, D ;
BENLLOCH, J ;
BENSINGER, J ;
BERETVAS, A ;
BERGE, JP ;
BERTOLUCCI, S ;
BIERY, K ;
BHADRA, S ;
BINKLEY, M ;
BISELLO, D ;
BLAIR, R ;
BLOCKER, C ;
BODEK, A ;
BOLOGNESI, V ;
BOOTH, AW ;
BOSWELL, C ;
BRANDENBURG, G ;
BROWN, D ;
BUCKLEYGEER, E ;
BUDD, HS ;
BUSETTO, G ;
BYONWAGNER, A ;
BYRUM, KL ;
CAMPAGNARI, C ;
CAMPBELL, M ;
CANER, A .
PHYSICAL REVIEW D, 1994, 50 (09) :5550-5561
[2]   MUON SYSTEM BASED ON STREAMER TUBES WITH TIME-DIFFERENCE READOUT [J].
AULCHENKO, VM ;
BAIBUSINOV, BO ;
CHILINGAROV, AG ;
LELCHUK, MY ;
NOMEROTSKY, AB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 265 (1-2) :137-140
[3]  
BANTLY J, 1997, FERMILABTM1995
[4]  
*CDF, 1996, FERMILABPUB96390E CD
[5]   Luminosity monitoring and measurement at CDF [J].
Cronin-Hennessy, D ;
Beretvas, A ;
Derwent, PF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 443 (01) :37-50
[6]   Luminosity monitor based on Cherenkov counters for p(p)over-bar colliders [J].
Elias, J ;
Klimenko, S ;
Konigsberg, J ;
Korytov, A ;
Mitselmakher, G ;
Nomerotski, A ;
Northacker, D ;
Safonov, A ;
Vidal, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 441 (03) :366-373