A new method for the remote collection of nasal and exhaled nitric oxide

被引:10
作者
Djupesland, G
Qian, W
Haight, JSJ
机构
[1] Ullevaal Univ Hosp, Dept Otorhinolaryngol, Oslo, Norway
[2] St Michaels Hosp, Dept Otolaryngol, Toronto, ON M5B 1W8, Canada
关键词
asthma; gas; lungs; nitric oxide; nose; off-line; rhinitis;
D O I
10.1378/chest.120.5.1645
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objectives: The present study introduces a method that has been developed to improve the remote collection and transportation of gas samples from the nose and lungs. Design: Assessment of agreement between two methods of clinical measurements. Setting: Noninvasive exhaled gas measurement at a respiratory research laboratory. Participants: Ten nonsmoking adult volunteers (median age, 44 years; age range, 33 to 53 years; men, 6; women, 4) were recruited. Measurements and results: Exhaled nitric oxide (ENO) and nasal nitric oxide (NNO) outputs were measured directly (on-line) and remotely (off-line). With the velum closed, lung air was exhaled at fixed flows (ie, 6, 8, and 10 L/min) (ENO) or room-air was aspirated through the nose in series at one fixed flow (ie, 5 to 8 L/min) (NNO). The off-line nitric oxide (NO) measurements were achieved by a gas collection tube system, which consisted of a flow control unit, a tube reservoir with one-way valves at both ends, and an interrupter valve allowing the trapping of gas inside the tube and eliminating the inclusion of "dead space." After clamping, the reservoir may store and transport the gas samples for delayed analysis. The coefficient of variation of three consecutive NO measurements was < 3% for both on-line and off-line ENO and NNO. The correlations between on-line and off-line measurements in both ENO and NNO outputs were high (r = 0.99; R-2 = 0.99), and, unlike previous studies using bag-collection, the ENO outputs for on-line and off-line measurements were in good agreement (Bland-Altman test) at all flows tested. Conclusions: The tube gas collection system eliminates the dead space and contamination during the gas sampling and permits the cost-effective and reliable off-line collection of both nasal and exhaled gas samples.
引用
收藏
页码:1645 / 1650
页数:6
相关论文
共 8 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Nitric oxide in the nasal airway: A new dimension in otorhinolaryngology [J].
Djupesland, PG ;
Chatkin, JM ;
Qian, W ;
Haight, JSJ .
AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2001, 22 (01) :19-32
[3]  
Jöbsis Q, 1999, EUR RESPIR J, V13, P1406
[4]  
Lundberg J, 1996, ACTA PHYSIOL SCAND, V157, P1
[5]   Exhalation flow and pressure-controlled reservoir collection of exhaled nitric oxide for remote and delayed analysis [J].
Paredi, P ;
Loukides, S ;
Ward, S ;
Cramer, D ;
Spicer, M ;
Kharitonov, SA ;
Barnes, PJ .
THORAX, 1998, 53 (09) :775-779
[6]  
Qian W., 1999, Rhinology (Utrecht), V37, P61
[7]   A method for the standardized offline collection of exhaled nitric oxide [J].
Silkoff, PE ;
Stevens, A ;
Pak, J ;
Bucher-Bartelson, B ;
Martin, RJ .
CHEST, 1999, 116 (03) :754-759
[8]  
Slutsky AS, 1999, AM J RESP CRIT CARE, V160, P2104