Biological variation of seminal parameters in healthy subjects

被引:115
作者
Alvarez, C
Castilla, JA [1 ]
Martínez, L
Ramírez, JP
Vergara, F
Gaforio, JJ
机构
[1] Hosp Virgen de las Nieves, Unidad Reprod, E-18014 Granada, Spain
[2] Clin Avicena, Unidad Reprod, Jaen, Spain
[3] CEIFER, Granada, Spain
[4] Univ Jaen, Dept Ciencias Salud, Jaen, Spain
关键词
analytical goals; analytical variation; biological variation; semen;
D O I
10.1093/humrep/deg430
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
BACKGROUND: A study was undertaken to assess the components of biological variation of seminal parameters in healthy subjects. METHODS: Twenty donor candidates were included in a 10-week follow-up study. Within- and between-subject biological variation, indices of individuality and heterogeneity, coefficient of reliability, critical differences, analytical goals and the lowest value observed with a <5% probability of having a true value less than the World Health Organization (1999) reference value were estimated for the following seminal parameters: concentration, total motility (WHO grades a + b + c), progressive motility (grades a + b), rapid progressive motility (grade a), sperm morphology and vitality. All analysis was performed by a single technician according to WHO 1999 guidelines for routine semen analysis. Analytical variation was assessed on different types of quality control material (frozen straws, sperm suspension, videotape, and slides) and at different (low, medium, high) quality levels. RESULTS: The analytical variation observed depended on the quality control material used and the level of semen quality. Concentration was the semen parameter with highest within- and between-subject variation, and vitality the lowest. Indices of individuality were all <0.7, and coefficients of reliability were high (0.68-0.84). The critical difference for sequential values significant at P < 0.05 for vitality, progressive motility and morphology (34.4, 49.2 and 58.0% respectively) were lower than for concentration (77.8%). CONCLUSIONS: The study results showed that conventional reference values for seminal parameters have little diagnostic value because of their marked individuality, though seminal parameters can be useful for assessing differences in an individual's serial results, in particular of progressive motility, morphology and vitality.
引用
收藏
页码:2082 / 2088
页数:7
相关论文
共 41 条
  • [1] Sperm morphological defects related to environment, lifestyle and medical history of 1001 male partners of pregnant women from four European cities
    Auger, J
    Eustache, F
    Andersen, AG
    Irvine, DS
    Jorgensen, N
    Skakkebæk, NE
    Suominen, J
    Toppari, J
    Vierula, M
    Jouannet, P
    [J]. HUMAN REPRODUCTION, 2001, 16 (12) : 2710 - 2717
  • [2] Relation between semen quality and fertility:: a population-based study of 430 first-pregnancy planners
    Bonde, JPE
    Ernst, E
    Jensen, TK
    Hjollund, NHI
    Kolstad, H
    Henriksen, TB
    Scheike, T
    Giwercman, A
    Olsen, J
    Skakkebæk, NE
    [J]. LANCET, 1998, 352 (9135) : 1172 - 1177
  • [3] BOSTOFTE E, 1987, ANDROLOGIA, V19, P76
  • [4] IMPLEMENTING COMPREHENSIVE QUALITY-CONTROL IN THE ANDROLOGY LABORATORY
    CLEMENTS, S
    COOKE, ID
    BARRATT, CLR
    [J]. HUMAN REPRODUCTION, 1995, 10 (08) : 2096 - 2106
  • [5] COOPER TG, 1992, FERTIL STERIL, V58, P172
  • [6] COTLOVE E, 1970, CLIN CHEM, V16, P1028
  • [7] PROCESSING DATA FOR OUTLIERS
    DIXON, WJ
    [J]. BIOMETRICS, 1953, 9 (01) : 74 - 89
  • [8] Fraser C. G., 2001, BIOL VARIATION PRINC
  • [9] FRASER CG, 1988, ARCH PATHOL LAB MED, V112, P404
  • [10] FRASER CG, 1989, CRIT REV CL LAB SCI, V27, P409