A high throughput method for the detection of metalloproteins on a microgram scale

被引:34
作者
Högbom, M
Ericsson, UB
Lam, R
Bakali, MA
Kuznetsova, E
Nordlund, P
Zamble, DB
机构
[1] Uppsala Univ, Dept Cell & Mol Biol, Biomed Ctr, SE-75124 Uppsala, Sweden
[2] Stockholm Univ, Dept Biochem & Biophys, SE-10691 Stockholm, Sweden
[3] Affinium Pharmaceut, Toronto, ON M5J 1V6, Canada
[4] Univ Toronto, Banting & Best Dept Med Res, Toronto, ON M5G 1L6, Canada
[5] Univ Toronto, Lash Miller Chem Labs, Dept Chem, Toronto, ON M5S 3H6, Canada
关键词
D O I
10.1074/mcp.T400023-MCP200
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Proteins that bind transition metals make up a substantial portion of the proteome, and the identification of a metal cofactor in a protein can greatly facilitate its functional assignment and help place it in the context of known cellular pathways. Existing methods for the detection of metalloproteins generally consume large amounts of protein, require expensive equipment, or are very labor intensive, rendering them unsuitable for use in high throughput proteomic initiatives. Here we present a method for the identification of metalloproteins that contain iron, copper, manganese, cobalt, nickel, and/or zinc that is sensitive, quick, robust, inexpensive, and can be performed with standard laboratory equipment. The assay is based on a combination of chemiluminescence and colorimetric detection methods, it typically consumes only 10 mu g of protein, and most common chemical components of protein solutions do not interfere with metal detection. Analysis of 52 protein samples was compared with the results from inductively coupled plasma-atomic emission spectrometry to verify the accuracy and sensitivity of the method. The assay is conducted in a 384-well format and requires about 3 h for completion, including a 2-h wait; so whole proteomes can be assayed for metal content in a matter of days.
引用
收藏
页码:827 / 834
页数:8
相关论文
共 30 条
[1]   CHEMILUMINESCENCE DETERMINATION OF IRON(II) AND TITANIUM(III) BY FLOW-INJECTION ANALYSIS BASED ON REACTIONS WITH AND WITHOUT LUMINOL [J].
ALWARTHAN, AA ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1987, 196 :135-140
[2]   A high-performance liquid chromatography method for determining transition metal content in proteins [J].
Atanassova, A ;
Lam, R ;
Zamble, DB .
ANALYTICAL BIOCHEMISTRY, 2004, 335 (01) :103-111
[3]   Bioinorganic chemistry in the postgenomic era [J].
Bertini, I ;
Rosato, A .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (07) :3601-3604
[4]   A tour of structural genomics [J].
Brenner, SE .
NATURE REVIEWS GENETICS, 2001, 2 (10) :801-809
[5]   A comprehensive experimental study of industrial, domestic and environmental interferences with the forensic luminol test for blood [J].
Creamer, JI ;
Quickenden, TI ;
Apanah, MV ;
Kerr, KA ;
Robertson, P .
LUMINESCENCE, 2003, 18 (04) :193-198
[6]   Jolly SAD [J].
Dauter, Z ;
Dauter, M ;
Dodson, E .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 2002, 58 :494-506
[7]   Is it jolly SAD? [J].
Dodson, E .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2003, 59 :1958-1965
[8]   Biological inorganic chemistry at the beginning of the 21st century [J].
Gray, HB .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (07) :3563-3568
[9]   PHASE DETERMINATION BY MULTIPLE-WAVELENGTH X-RAY-DIFFRACTION - CRYSTAL-STRUCTURE OF A BASIC BLUE COPPER PROTEIN FROM CUCUMBERS [J].
GUSS, JM ;
MERRITT, EA ;
PHIZACKERLEY, RP ;
HEDMAN, B ;
MURATA, M ;
HODGSON, KO ;
FREEMAN, HC .
SCIENCE, 1988, 241 (4867) :806-811
[10]   Synchrotron techniques for metalloproteins and human disease in post genome era [J].
Hasnain, SS .
JOURNAL OF SYNCHROTRON RADIATION, 2004, 11 (01) :7-11