Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry at 11.5 tesla: Instrument design and initial results

被引:44
作者
Gorshkov, MV [1 ]
Tolic, LP [1 ]
Udseth, HR [1 ]
Anderson, GA [1 ]
Huang, BM [1 ]
Bruce, JE [1 ]
Prior, DC [1 ]
Hofstadler, SA [1 ]
Tang, LA [1 ]
Chen, LZ [1 ]
Willett, JA [1 ]
Rockwood, AL [1 ]
Sherman, MS [1 ]
Smith, RD [1 ]
机构
[1] Pacific NW Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
关键词
D O I
10.1016/S1044-0305(98)00037-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Initial results obtained using a new electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) mass spectrometer operated at a magnetic field 11.5 tesla are presented. The new instrument utilized an electrostatic ion guide between the ESI source and FTICR trap that provided up to 5% overall transmission efficiency for Light ions and up to 30% efficiency for heavier biomolecules. The higher magnetic field in combination with an enlarged FTICR ion trap made it possible to substantially improve resolving power and operate in a more robust fashion for large biopolymers compared to lower field instruments. Mass resolution up to 10(6) has been achieved for intermediate size biopolymers such as bovine ubiquitin (8.6 kDa) and bovine cytochrome c (12.4 kDa) without the use of frequency drift correction methods. A mass resolution of 370,000 has been demonstrated for isotopically resolved molecular ions of bovine serum albumin (66.5 kDa). Comparative measurements were made with the same spectrometer using a lower field 3.5-tesla magnet allowing the performance gains to be more readily quantified. Further improvements in pumping capacity of the vacuum system and efficiency of ion transmission from the source are expected to lead to further substantial sensitivity gains. (C) 1998 American Society for Mass Spectrometry.
引用
收藏
页码:692 / 700
页数:9
相关论文
共 31 条
  • [1] ANDERSON GA, 1995, ICR2LS PAC NW NAT LA
  • [2] FOURIER-TRANSFORM ELECTROSPRAY INSTRUMENTATION FOR TANDEM HIGH-RESOLUTION MASS-SPECTROMETRY OF LARGE MOLECULES
    BEU, SC
    SENKO, MW
    QUINN, JP
    WAMPLER, FM
    MCLAFFERTY, FW
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) : 557 - 565
  • [3] IMPROVED FOURIER-TRANSFORM ION-CYCLOTRON-RESONANCE MASS-SPECTROMETRY OF LARGE BIOMOLECULES
    BEU, SC
    SENKO, MW
    QUINN, JP
    MCLAFFERTY, FW
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (02) : 190 - 192
  • [4] ION TRAPPING AND MANIPULATION IN A TANDEM TIME-OF-FLIGHT-FOURIER TRANSFORM MASS-SPECTROMETER
    BEU, SC
    LAUDE, DA
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 104 (02): : 109 - 127
  • [5] THE ACCURACY OF HEAVY-ION MASS MEASUREMENTS USING TIME OF FLIGHT-ION CYCLOTRON-RESONANCE IN A PENNING TRAP
    BOLLEN, G
    MOORE, RB
    SAVARD, G
    STOLZENBERG, H
    [J]. JOURNAL OF APPLIED PHYSICS, 1990, 68 (09) : 4355 - 4374
  • [6] TIME-BASE MODULATION FOR THE CORRECTION OF CYCLOTRON FREQUENCY-SHIFTS OBSERVED IN LONG-LIVED TRANSIENTS FROM FOURIER-TRANSFORM ION-CYCLOTRON-RESONANCE MASS-SPECTROMETRY OF ELECTROSPRAYED BIOPOLYMERS
    BRUCE, JE
    ANDERSON, GA
    HOFSTADLER, SA
    WINGER, BE
    SMITH, RD
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (08) : 700 - 703
  • [7] Large molecule characterization based upon individual ion detection with electrospray ionization-FTICR mass spectrometry
    Bruce, JE
    Anderson, GA
    Udseth, HR
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (03) : 519 - 525
  • [8] FREQUENCY-SWEEP FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY
    COMISARO.MB
    MARSHALL, AG
    [J]. CHEMICAL PHYSICS LETTERS, 1974, 26 (04) : 489 - 490
  • [9] FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY
    COMISAROW, MB
    MARSHALL, AG
    [J]. CHEMICAL PHYSICS LETTERS, 1974, 25 (02) : 282 - 283
  • [10] ELECTROSPRAY IONIZATION-PRINCIPLES AND PRACTICE
    FENN, JB
    MANN, M
    MENG, CK
    WONG, SF
    WHITEHOUSE, CM
    [J]. MASS SPECTROMETRY REVIEWS, 1990, 9 (01) : 37 - 70