Comparative examination of the accuracy of a mechanical and an optical system in CT and MRT based instrument navigation

被引:28
作者
Hassfeld, S [1 ]
Mühling, J [1 ]
机构
[1] Univ Heidelberg Hosp, Dept Maxillofacial & Craniofacial Surg, Heidelberg, Germany
关键词
computer-assisted surgery; image guided surgery; navigation systems; application accuracy;
D O I
10.1016/S0901-5027(00)80069-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of an intraoperative instrument navigation system is to support the surgeon in the localization of anatomical regions and to guide the use of surgical instruments. An overview of technical principles and literature reports on various navigation systems is provided here. The navigation accuracy (tested on a plastic phantom under simulated operating room conditions) of the mechanical Viewing Wand system and the optical SPOCS system amounts to 1 to 3 mm for computerized tomography (CT) data, with a significant inverse dependence on the layer thickness. The values for magnetic resonance tomography (MRT) data are significantly higher. In regard to the choice of registration points, a statistically inverse dependence exists between the number of points and the distance between the points. During the time period between autumn 1993 and mid-1999, more than 120 clinical applications were performed. The intraoperative accuracy was in the range of less than or equal to3 mm. Registering the patient position with preoperatively inserted screw markers achieved accuracy values of less than or equal to2 mm. The instrument navigation technique has proved to be very advantageous for the spatial orientation of the surgeons. The possibility of checking resection borders has opened up new perspectives in tumor surgery. A quality improvement and a reduction of the operational risks as well as a considerable decline in the stress placed on the patient can be expected in the near future due the techniques of computer-assisted surgery.
引用
收藏
页码:400 / 407
页数:8
相关论文
共 29 条
  • [1] COMPUTER-ASSISTED SURGERY
    ADAMS, L
    KRYBUS, W
    MEYEREBRECHT, D
    RUEGER, R
    GILSBACH, JM
    MOESGES, R
    SCHLOENDORFF, G
    [J]. IEEE COMPUTER GRAPHICS AND APPLICATIONS, 1990, 10 (03) : 43 - 51
  • [2] Clinical use of the optical digitizer for intracranial neuronavigation
    Germane, IM
    Villalobos, H
    Silvers, A
    Post, KD
    [J]. NEUROSURGERY, 1999, 45 (02) : 261 - 269
  • [3] CLINICAL USE OF A FRAMELESS STEREOTAXIC ARM - RESULTS OF 325 CASES
    GOLFINOS, JG
    FITZPATRICK, BC
    SMITH, LR
    SPETZLER, RF
    [J]. JOURNAL OF NEUROSURGERY, 1995, 83 (02) : 197 - 205
  • [4] BrainLab VectorVision neuronavigation system: Technology and clinical experiences in 131 cases
    Gumprecht, HK
    Widenka, DC
    Lumenta, CB
    [J]. NEUROSURGERY, 1999, 44 (01) : 97 - 104
  • [5] Preoperative planning and intraoperative navigation in skull base surgery
    Hassfeld, S
    Zoller, J
    Albert, FK
    Wirtz, CR
    Knauth, M
    Muhling, J
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1998, 26 (04) : 220 - 225
  • [6] HASSFELD S, 1995, INT J ORAL MAX SURG, V24, P111
  • [7] Hassfeld S, 1998, Comput Aided Surg, V3, P183, DOI 10.1002/(SICI)1097-0150(1998)3:4<183::AID-IGS8>3.0.CO
  • [8] 2-F
  • [9] Intraoperative guidance in maxillofacial and craniofacial surgery
    Hassfeld, S
    Muehling, J
    Wirtz, CR
    Knauth, M
    Lutze, T
    Schulz, HJ
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (04) : 277 - 283
  • [10] Optical tracking of a microscope for image-guided intranasal sinus surgery
    Hauser, R
    Westermann, B
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1999, 108 (01) : 54 - 62