Simulation study of magnetic resonance imaging-guided cortically constrained diffuse optical tomography of human brain function

被引:125
作者
Boas, DA [1 ]
Dale, AM [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Athinoula A Martinos Ctr Biomed Imaging, Boston, MA 02129 USA
关键词
D O I
10.1364/AO.44.001957
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Diffuse optical imaging can measure brain activity noninvasively in humans through the scalp and skull by measuring the light intensity modulation arising from localized-activity-induced absorption changes within the cortex. Spatial resolution and localization accuracy are currently limited by measurement geometry to approximately 3 cm in the plane parallel to the scalp. Depth resolution is a more significant challenge owing to the limited angle tomography permitted by reflectance-only measurements. We combine previously established concepts for improving image quality and demonstrate, through simulation studies, their application for improving the image quality of adult human brain function. We show in a three-dimensional human head model that localization accuracy is significantly improved by the addition of measurements that provide overlapping samples of brain tissue. However, the reconstructed absorption contrast is significantly underestimated because its depth is underestimated. We show that the absorption contrast amplitude accuracy can be significantly improved by providing a cortical spatial constraint in the image reconstruction to obtain a better depth localization. The cortical constraint makes physiological sense since the brain-activity-induced absorption changes are occurring in the cortex and not in the scalp, skull, and cerebral spinal fluid. This spatial constraint is provided by segmentation of coregistered structural magnetic resonance imaging (MRI). However, the absorption contrast deep within the cortex is reconstructed superficially, resulting in an underestimation of the absorption contrast. The synthesis of techniques described here indicates that multimodality imaging of brain function with diffuse optical imaging and MRI has the potential to provide more quantitative estimates of the total and deoxyhemoglobin response to brain activation, which is currently not provided by either method independently. However, issues of depth resolution within the cortex remain to be resolved. (c) 2005 Optical Society of America.
引用
收藏
页码:1957 / 1968
页数:12
相关论文
共 57 条
  • [1] Arridge SR, 2000, INT J IMAG SYST TECH, V11, P2, DOI 10.1002/(SICI)1098-1098(2000)11:1<2::AID-IMA2>3.0.CO
  • [2] 2-J
  • [3] Optical tomography in medical imaging
    Arridge, SR
    [J]. INVERSE PROBLEMS, 1999, 15 (02) : R41 - R93
  • [4] ARRIDGE SR, 1993, INFORMATION PROCESSI
  • [5] Frontal lobe activation during object permanence: Data from near-infrared spectroscopy
    Baird, AA
    Kagan, J
    Gaudette, T
    Walz, KA
    Hershlag, N
    Boas, DA
    [J]. NEUROIMAGE, 2002, 16 (04) : 1120 - 1126
  • [6] MRI-guided optical tomography: Prospects and computation for a new imaging method
    Barbour, RL
    Graber, HL
    Chang, JW
    Barbour, SLS
    Koo, PC
    Aronson, R
    [J]. IEEE COMPUTATIONAL SCIENCE & ENGINEERING, 1995, 2 (04): : 63 - 77
  • [7] Robust inference of baseline optical properties of the human head with three-dimensional segmentation from magnetic resonance imaging
    Barnett, AH
    Culver, JP
    Sorensen, AG
    Dale, A
    Boas, DA
    [J]. APPLIED OPTICS, 2003, 42 (16) : 3095 - 3108
  • [8] In vivo local determination of tissue optical properties:: applications to human brain
    Bevilacqua, F
    Piguet, D
    Marquet, P
    Gross, JD
    Tromberg, BJ
    Depeursinge, C
    [J]. APPLIED OPTICS, 1999, 38 (22) : 4939 - 4950
  • [9] Three-dimensional optical tomography of hemodynamics in the human head
    Bluestone, AY
    Abdoulaev, G
    Schmitz, CH
    Barbour, RL
    Hielscher, AH
    [J]. OPTICS EXPRESS, 2001, 9 (06): : 272 - 286
  • [10] Improving the diffuse optical imaging spatial resolution of the cerebral hemodynamic response to brain activation in humans
    Boas, DA
    Chen, K
    Grebert, D
    Franceschini, MA
    [J]. OPTICS LETTERS, 2004, 29 (13) : 1506 - 1508