Fine-needle aspiration biopsy of nonpalpable breast lesions in a multicenter clinical trial: Results from the radiologic diagnostic oncology group V

被引:101
作者
Pisano, ED
Fajardo, LL
Caudry, DJ
Sneige, N
Frable, WJ
Berg, WA
Tocino, I
Schnitt, SJ
Connolly, JL
Gatsonis, CA
McNeil, BJ
机构
[1] Univ N Carolina, Dept Radiol, Chapel Hill, NC 27599 USA
[2] Johns Hopkins Univ, Dept Radiol, Baltimore, MD USA
[3] MD Anderson Comprehens Canc Ctr, Dept Pathol, Houston, TX USA
[4] Virginia Commonwealth Univ, Med Coll Virginia, Dept Pathol, Richmond, VA USA
[5] Brown Univ, Ctr Stat Sci, Providence, RI 02912 USA
[6] Univ Maryland, Dept Radiol, Baltimore, MD 21201 USA
[7] Yale Univ, Dept Radiol, New Haven, CT USA
[8] Harvard Univ, Sch Med, Dept Pathol, Boston, MA USA
[9] Harvard Univ, Sch Med, Dept Hlth Care Policy, Boston, MA USA
[10] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[11] Harvard Univ, Sch Med, Boston, MA USA
关键词
breast; biopsy; breast neoplasms; US; stereotaxis;
D O I
10.1148/radiology.219.3.r01jn28785
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the diagnostic accuracy of ultrasonographically (US) and stereotactically guided fine-needle aspiration biopsy (FNAB) in the diagnosis of nonpalpable breast lesions. MATERIALS AND METHODS: At 18 institutions, 442 women who underwent 22-25-gauge imaging-guided FNAB were enrolled. Definitive surgical, core-needle biopsy, and/or follow-up information was available for 423 (95.7%) of these women. The reference standard was established from additional clinical and imaging information for an additional six (1.4%) women who did not undergo further histopathologic evaluation. The FNAB protocol was standardized at all institutions, and all specimens were reread by one of two expert cytopathologists. RESULTS: When insufficient samples were included in the analysis and classified as positive, the sensitivity and specificity of FNAB were 85%-88% and 55.6%-90.5%, respectively; accuracy ranged from 62.2% to 89.2%. The diagnostic accuracy of FNAB was significantly better for detection of masses than for detection of calcifications (67.3% vs 53.8%, P = .006) and with US guidance than with stereotactic guidance (77.2% vs 58.9%; P = .002). CONCLUSION: FNAB of nonpalpable breast lesions has limited value given the high insufficient sample rate and greater diagnostic accuracy of other interventions, including core-needle biopsy and needle-localized open surgical biopsy.
引用
收藏
页码:785 / 792
页数:8
相关论文
共 47 条
[1]  
Abati A, 1997, DIAGN CYTOPATHOL, V16, P295
[2]   STEREOTACTIC FINE-NEEDLE BIOPSY IN 2594 MAMMOGRAPHICALLY DETECTED NON-PALPABLE LESIONS [J].
AZAVEDO, E ;
SVANE, G ;
AUER, G .
LANCET, 1989, 1 (8646) :1033-1036
[3]   THE PREVALENCE OF CARCINOMA IN PALPABLE VS IMPALPABLE, MAMMOGRAPHICALLY DETECTED LESIONS [J].
BASSETT, LW ;
LIU, TH ;
GIULIANO, AE ;
GOLD, RH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) :21-24
[4]  
BIBBO M, 1988, ACTA CYTOL, V32, P193
[5]  
Boerner S, 1999, CANCER CYTOPATHOL, V87, P19, DOI 10.1002/(SICI)1097-0142(19990225)87:1<19::AID-CNCR4>3.0.CO
[6]  
2-K
[7]   The positive predictive value of mammographic signs: A review of 425 non-palpable breast lesions [J].
Burrell, HC ;
Pinder, SE ;
Wilson, ARM ;
Evans, AJ ;
Yeoman, LJ ;
Elston, CW ;
Ellis, IO .
CLINICAL RADIOLOGY, 1996, 51 (04) :277-281
[8]  
Ciatto S, 1997, ACTA RADIOL, V38, P815
[9]   PERFORMANCE OF FINE-NEEDLE ASPIRATION CYTOLOGY OF THE BREAST-MULTICENTER STUDY OF 23,063 ASPIRATES IN 10 ITALIAN LABORATORIES [J].
CIATTO, S ;
BONARDI, R ;
CARIAGGI, MP .
TUMORI, 1995, 81 (01) :13-17
[10]   NONPALPABLE BREAST-LESIONS - STEREOTAXIC FINE-NEEDLE ASPIRATION CYTOLOGY [J].
CIATTO, S ;
DELTURCO, MR ;
BRAVETTI, P .
RADIOLOGY, 1989, 173 (01) :57-59