Mechanical properties of native and ex vivo remodeled porcine saphenous veins

被引:38
作者
Gusic, RJ
Petko, M
Myung, R
Gaynor, JW
Gooch, KJ [1 ]
机构
[1] Univ Penn, Dept Bioengn, Inst Med & Engn, Philadelphia, PA 19104 USA
[2] Childrens Hosp Philadelphia, Dept Cardiothorac Surg, Philadelphia, PA 19104 USA
关键词
mechanics; hypertrophy; eutrophic remodeling; vein graft;
D O I
10.1016/j.jbiomech.2005.04.002
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
When grafted into an arterial environment in vivo, veins remodel in response to the new mechanical environment, thereby changing their mechanical properties and potentially impacting their patency as bypass grafts. Porcine saphenous veins were subjected for one week to four different ex vivo hemodynamic environments in which pressure and shear stress were varied independently, as well as an environment that mimicked that of an arterial bypass graft. After one week of ex vivo culture, the mechanical properties of intact saphenous veins were evaluated to relate specific aspects of the mechanical environment to vein remodeling and corresponding changes in mechanics. The compliance of all cultured veins tended to be less than that of fresh veins; however, this trend was more due to changes in medial and luminal areas than changes in the intrinsic properties of the vein wall. A combination of medial hypertrophy and eutrophic remodeling leads to significantly smaller (p<0.05) wall stresses measured in all cultured veins except those subjected to bypass graft conditions relative to stresses measured in fresh veins at corresponding pressures. Our results suggest that the mechanical environment effects changes in vessel size, as well as the nature of the remodeling, which contribute to altering vein mechanical properties. (C) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1770 / 1779
页数:10
相关论文
共 23 条
[1]   EFFECT OF COMPLIANCE MISMATCH ON VASCULAR GRAFT PATENCY [J].
ABBOTT, WM ;
MEGERMAN, J ;
HASSON, JE ;
LITALIEN, G ;
WARNOCK, DF .
JOURNAL OF VASCULAR SURGERY, 1987, 5 (02) :376-382
[2]   MECHANICS OF CEREBRAL ARTERIOLES IN HYPERTENSIVE RATS [J].
BAUMBACH, GL ;
DOBRIN, PB ;
HART, MN ;
HEISTAD, DD .
CIRCULATION RESEARCH, 1988, 62 (01) :56-64
[3]   Spontaneously hypertensive rat resistance artery structure related to myogenic and mechanical properties [J].
Bund, SJ .
CLINICAL SCIENCE, 2001, 101 (04) :385-393
[4]   CONDUIT OPTIONS IN CORONARY-ARTERY BYPASS-SURGERY [J].
CANVER, CC .
CHEST, 1995, 108 (04) :1150-1155
[5]   Transmural pressure induces matrix-degrading activity in porcine arteries ex vivo [J].
Chesler, NC ;
Ku, DN ;
Galis, ZS .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 277 (05) :H2002-H2009
[6]   Smooth muscle relaxation and local hydraulic impedance properties of the aorta [J].
Cholley, BP ;
Lang, RM ;
Korcarz, CE ;
Shroff, SG .
JOURNAL OF APPLIED PHYSIOLOGY, 2001, 90 (06) :2427-2438
[7]   Mechanical environment, donor age, and presence of endothelium interact to modulate porcine artery viability ex vivo [J].
Clerin, V ;
Gusic, RJ ;
O'Brien, J ;
Kirshbom, PM ;
Myung, RJ ;
Gaynor, JW ;
Gooch, KJ .
ANNALS OF BIOMEDICAL ENGINEERING, 2002, 30 (09) :1117-1127
[8]   Tissue engineering of arteries by directed remodeling of intact arterial segments [J].
Clerin, V ;
Nichol, JW ;
Petko, M ;
Myung, RJ ;
Gaynor, JW ;
Gooch, KJ .
TISSUE ENGINEERING, 2003, 9 (03) :461-472
[9]   COMPARISON OF CAROTID-ARTERY MECHANICS IN RAT, RABBIT, AND DOG [J].
COX, RH .
AMERICAN JOURNAL OF PHYSIOLOGY, 1978, 234 (03) :H280-H288
[10]   VEIN COMPLIANCE - A PREOPERATIVE INDICATOR OF VEIN MORPHOLOGY AND OF VEINS AT RISK OF VASCULAR GRAFT STENOSIS [J].
DAVIES, AH ;
MAGEE, TR ;
BAIRD, RN ;
SHEFFIELD, E ;
HORROCKS, M .
BRITISH JOURNAL OF SURGERY, 1992, 79 (10) :1019-1021