A robotic-flow injection approach to the fully automated determination of starch in food

被引:12
作者
VelascoArjona, A [1 ]
deCastro, MDL [1 ]
机构
[1] UNIV CORDOBA, FAC SCI, DEPT ANALYT CHEM, E-14004 CORDOBA, SPAIN
关键词
robot; flow injection; microwave digester; starch; solid samples; REDUCING SUGARS; SOIL;
D O I
10.1016/0003-2670(96)00184-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fully automated method for the determination of starch in foodstuff was developed. The method is based on the standard procedure involving leaching of sugars from the sample, hydrolysis of the analyte, and colorimetric determination of the hydrolysis products (sugars) by the neocuproine method. A focused microwave digester is used as a peripheral for the robotic station in order to expedite analyses by accelerating the hydrolysis step. The station is connected to a flow injection manifold, which minimizes the dilution and derivatization times. In this way, duplicate analyses of three solid samples take 5 h rather than 15 h required when the whole analytical sequence is performed by the robotic station and 5 h per sample taken by the manual method.
引用
收藏
页码:205 / 213
页数:9
相关论文
共 15 条
[1]   DETERMINATION OF SOIL-PH USING A LABORATORY ROBOT [J].
BRENES, N ;
QUIGLEY, MN ;
REID, WS .
ANALYTICA CHIMICA ACTA, 1995, 310 (02) :319-327
[2]   USE OF FOCUSED MICROWAVES FOR EXPEDITIVE SHORTENING OF SAMPLE PRETREATMENT - DIGESTION AND REDUCTION PROCEDURES PRIOR TO SELENIUM SPECIATION AS SELENIUM(IV) OR SELENIUM(VI) [J].
BRYCE, DW ;
IZQUIERDO, A ;
DECASTRO, MDL .
ANALYST, 1995, 120 (08) :2171-2174
[3]   Speciation of inorganic selenium using flow injection hydride generation atomic fluorescence spectrometry [J].
Bryce, DW ;
Izquierdo, A ;
DeCastro, MDL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (12) :1059-1063
[4]   COUPLED ROBOT-FLOW INJECTION-ANALYSIS SYSTEM FOR FULLY AUTOMATED-DETERMINATION OF TOTAL POLYPHENOLS IN OLIVE OIL [J].
GARCIAMESA, JA ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1993, 65 (23) :3540-3542
[5]  
GARCIAMESA JA, 1993, J FLOW INJECTION ANA, V10, P262
[6]   DETERMINATION OF REDUCING SUGARS IN WINE BY FLOW-INJECTION ANALYSIS [J].
MAQUIEIRA, A ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYST, 1987, 112 (11) :1569-1572
[7]   DETERMINATION OF THE OXIDATIVE STABILITY OF OLIVE OIL BY USE OF A ROBOTIC STATION [J].
MESA, JAG ;
DECASTRO, MDL ;
VALCARCEL, M .
TALANTA, 1993, 40 (11) :1595-1600
[8]   DETERMINATION OF REDUCING SUGARS BY THE NEOCUPROINE METHOD USING FLOW-INJECTION ANALYSIS [J].
PERISTORTAJADA, M ;
PUCHADES, R ;
MAQUIERIA, A .
FOOD CHEMISTRY, 1992, 43 (01) :65-69
[9]   USE OF A ROBOTIC STATION FOR FULL AUTOMATION OF THE DETERMINATION OF ORGANIC-MATTER IN SOIL AND FERTILIZERS [J].
TORRES, P ;
GARCIAMESA, JA ;
DECASTRO, MDL .
JOURNAL OF AUTOMATIC CHEMISTRY, 1994, 16 (05) :183-186
[10]   MICROWAVE-ASSISTED ROBOTIC METHOD FOR THE DETERMINATION OF TRACE-METALS IN SOIL [J].
TORRES, P ;
BALLESTEROS, E ;
DECASTRO, MDL .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :371-377