A new interference-free lysine biosensor using a non-conducting polymer film

被引:43
作者
Curulli, A
Kelly, S
O'Sullivan, C
Guilbault, GG
Palleschi, G
机构
[1] Studio Elettrochim & Chim Fis Interfasi, Ctr CNR, I-00161 Rome, Italy
[2] Natl Univ Ireland Univ Coll Cork, Cork, Ireland
[3] Univ Roma Tor Vergata, Dipartimento Sci & Tecnol Chim, Rome, Italy
关键词
non-conducting polymers; electropolymerisation; interferences; lysine; food analysis; lysine oxidase;
D O I
10.1016/S0956-5663(98)00075-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An electrochemical biosensor for the determination of lysine to be used for rapid evaluation of food quality has been developed. Platinum electrodes have been coated by electropolymerisation with 1,2-diaminobenzene( 1.2-DAB) using cyclic voltammetry. The reduction in the oxidation of interferents compared with the bare platinum electrode was 100% for ascorbic acid, 99% for acetaminophen and 99% for cysteine. The enzyme L-lysine-cu-oxidase was then immobilised onto the polymer layer by passive adsorption and a calibration curve for lysine constructed. This gave a linear range of 1 x 10(-5) mol/l to 1 x 10(-3) mol/l and a limit of detection of 2 x 10(-7) mel/l. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:1245 / 1250
页数:6
相关论文
共 19 条
[1]  
[Anonymous], 1986, HDB CONDUCTING POLYM
[2]   Electropolymerization of hydroxybenzene and aminobenzene isomers on platinum electrodes to assemble interference-free electrochemical biosensors [J].
Carelli, I ;
Chiarotto, I ;
Curulli, A ;
Palleschi, G .
ELECTROCHIMICA ACTA, 1996, 41 (11-12) :1793-1800
[3]   INTERFERENCE-FREE GLUCOSE SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN OVEROXIDIZED NONCONDUCTING POLYPYRROLE FILM [J].
CENTONZE, D ;
GUERRIERI, A ;
MALITESTA, C ;
PALMISANO, F ;
ZAMBONIN, PG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (09) :729-733
[4]   PERMEATION OF SOLUTES THROUGH AN ELECTROPOLYMERIZED ULTRATHIN POLY-O-PHENYLENEDIAMINE FILM USED AS AN ENZYME-ENTRAPPING MEMBRANE [J].
CENTONZE, D ;
MALITESTA, C ;
PALMISANO, F ;
ZAMBONIN, PG .
ELECTROANALYSIS, 1994, 6 (5-6) :423-429
[5]   MODIFICATION OF ELECTRODE SURFACES WITH OXIDIZED PHENOLS TO CONFER SELECTIVITY TO AMPEROMETRIC BIOSENSORS FOR GLUCOSE DETERMINATION [J].
CHRISTIE, IM ;
VADGAMA, P ;
LLOYD, S .
ANALYTICA CHIMICA ACTA, 1993, 274 (02) :191-199
[6]   Assembling and evaluation of new dehydrogenase enzyme electrode probes obtained by electropolymerization of aminobenzene isomers and PQQ on gold, platinum and carbon electrodes [J].
Curulli, A ;
Carelli, I ;
Trischitta, O ;
Palleschi, G .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (9-10) :1043-1055
[7]   USE OF POLYMER-FILMS IN AMPEROMETRIC BIOSENSORS [J].
EMR, SA ;
YACYNYCH, AM .
ELECTROANALYSIS, 1995, 7 (10) :913-923
[8]   ELECTROPOLYMERIZED FILMS TO PREVENT INTERFERENCES AND ELECTRODE FOULING IN BIOSENSORS [J].
GEISE, RJ ;
ADAMS, JM ;
BARONE, NJ ;
YACYNYCH, AM .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (02) :151-160
[9]   BIOSENSOR BASED ON CONDUCTING POLYMERS [J].
HOA, DT ;
KUMAR, TNS ;
PUNEKAR, NS ;
SRINIVASA, RS ;
LAL, R ;
CONTRACTOR, AQ .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :2645-2646
[10]   ELECTROCHEMICAL PREPARATION AND ANALYTICAL APPLICATIONS OF ULTRATHIN OVEROXIDIZED POLYPYRROLE FILMS [J].
HSUEH, CC ;
BRAJTERTOTH, A .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :2458-2464