Radiation environment on the mir orbital station during solar minimum

被引:26
作者
Badhwar, GD [1 ]
Atwell, W
Cash, B
Petrov, VM
Akatov, YA
Tchernykh, IV
Shurshakov, VA
Arkhangelsky, VA
机构
[1] NASA, Lyndon B Johnson Space Ctr, Houston, TX 77058 USA
[2] Inst Biomed Problems, Moscow 1000027, Russia
[3] Lockheed Martin, Houston, TX 77058 USA
[4] Rockwell Aerosp, Houston, TX 77058 USA
来源
LIFE SCIENCES: RECENT DOSIMETRY RESULTS, CHROMOSOME DAMAGE AND HERITABLE EFFECTS | 1998年 / 22卷 / 04期
关键词
D O I
10.1016/S0273-1177(98)01070-9
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
The Mir station has been in a 51.65 degrees inclination orbit since March 1986. In March 1995, the first US astronaut flew on the Mir-18 mission and returned on the Space Shuttle in July 1995. Since then three additional US astronauts have stayed on orbit for up to 6 months. Since the return of the first US astronaut, both the Spektr and Priroda modules have docked with Mir station, altering the mass shielding distribution. Radiation measurements, including the direct comparison of US and Russian absorbed dose rates in the Base Block of the Mir station, were made during the Mir-18 and -19 missions. There is a significant variation of dose rates across the core module; the six locations sampled showed a variation of a factor of nearly two. A tissue equivalent proportional counter (TEPC) measured a total absorbed dose rate of 300 mu Gy/day, roughly equally divided between the rate due to trapped protons from the South Atlantic Anomaly (SAA) and galactic cosmic radiation (GCR). This dose rate is about a factor of two lower than the rate measured by the thinly shielded (0.5 g cm(-2) of Al) operational ion chamber (R-16), and about 3/2 of the rate of the more heavily shielded (3.5 g cm(-2) of Al) ion chamber. This is due to the differences in the mass shielding properties at the location of these defectors. A comparison of integral linear energy transfer (LET) spectra measured by TEPC and plastic nuclear track detectors (PNTDs) deployed side by side are in remarkable agreement in the LET region of 15 - 1000 keV/mu m, where the PNTDs are fully efficient. The average quality factor, using the ICRP-26 definition, was 2.6, which is higher than normally used. There is-excellent agreement between the measured GCR dose rate and model calculations, but this is not true for trapped protons. The measured Mir-18 crew skin dose equivalent rate was 1133 mu Sv/day. Using the skin dose rate and anatomical models, we have estimated the blood-forming organ (BFO) dose rate and the maximum stay time in orbit for International Space Station crew members. Published by Elsevier Science Ltd on behalf of COSPAR.
引用
收藏
页码:501 / 510
页数:10
相关论文
共 9 条
[1]  
Badhwar G D, 1996, Adv Space Res, V17, P7, DOI 10.1016/0273-1177(95)00507-B
[2]   Measurements of the linear energy transfer spectra on the Mir orbital station and comparison with radiation transport models [J].
Badhwar, GD ;
Konradi, A ;
Atwell, W ;
Golightly, MJ ;
Cucinotta, FA ;
Wilson, JW ;
Petrov, VM ;
Tchernykh, IV ;
Shurshakov, VA ;
Lobakov, AP .
RADIATION MEASUREMENTS, 1996, 26 (02) :147-&
[3]  
BADHWAR GD, 1997, RADIAT MEAS, V26, P901
[4]  
BENGHIN VV, 1997, ADV SPACE RES, V17
[5]  
Bondarenko V A, 1995, Aviakosm Ekolog Med, V29, P64
[6]   Effects of target fragmentation on evaluation of LET spectra from space radiations: Implications for space radiation protection studies [J].
Cucinotta, FA ;
Wilson, JW ;
Shinn, JL ;
Badavi, FF ;
Badhwar, GD .
RADIATION MEASUREMENTS, 1996, 26 (06) :923-934
[7]  
DALY EJ, 1993, ESTECWMA93067ED EUR
[8]  
National Council on Radiation Protection and Measurements (NCRP), 1989, 98 NCRP
[9]  
Wilson J. W., 1991, NASA REFERENCE PUBLI, V1257